EUVIMEDEUVIMED entdecken
Crossref

Oxygen-induced dual-signal point-of-care testing aptasensor for aflatoxin B1 detection using platinum nanoparticle catalysis in visual fluorometry and gravimetry

Fang Luo, Linxiu Zhan, Ye Deng, Kun Qiao, Nan Pan, Zuquan Weng, Cuiying Lin, Bin Qiu, Zhenyu Lin

Analytica Chimica Acta · 2023

DOI: 10.1016/j.aca.2023.341544 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023. Verfasst von Fang Luo und 8 weiteren Autor:innen. Beteiligte Einrichtung: College of Biological Science and Engineering, Fuzhou University, Fuzhou, Fujian, 350116, China; MOE Key Laboratory of Analysis and Detection for Foo…. Hauptthemen laut MEDLINE: Metal Nanoparticles, Aptamers, Nucleotide, Biosensing Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: University of Newcastle Australia, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Point-of-care testing (POCT) has experienced rapid development owing to its advantages of rapid testing, low cost and strong operability, making it indispensable for analyte detection in outdoor or rural areas. In this study, we propose a novel method for the detection of aflatoxin B1 (AFB1) using a dual-signal readout approach within a unified system. This method employs dual channel modes, namely visual fluorescence and weight measurements, as the signal readouts. Specifically, a pressure-sensitive material is utilized as a visual fluorescent agent, its signal can be quenched in the presence of high oxygen pressure. Additionally, an electronic balance, commonly used for weight measurement, is adopted as another signal device, where the signal is generated through the catalytic decomposition of H2O2 by platinum nanoparticles. The experimental results demonstrate that the proposed device enables accurate AFB1 detection within the concentration range of 1.5-32 μg mL-1, with a detection limit of 0.47 μg mL-1. Moreover, this method has been successfully applied for practical AFB1 detection with satisfactory results. Notably, this study pioneers the use of a pressure-sensitive material as a visual signal in POCT. By addressing the limitations of single-signal readout approaches, our method fulfills requirements of intuitiveness, sensitivity, quantitative analysis and reusability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Metal NanoparticlesAptamers, NucleotideBiosensing TechniquesAflatoxin B1PlatinumHydrogen PeroxideLimit of DetectionFluorometryPoint-of-Care Testing

Stichwörter der Autor:innen

Dual-mode readoutFluorescencePlatinum nanoparticlesPoint-of-care testing

Substanzen

Aflatoxin B1PlatinumHydrogen PeroxideAptamers, Nucleotide

Autor:innen und Institutionen

  • College of Biological Science and Engineering, Fuzhou University, Fuzhou, Fujian, 350116, China; MOE Key Laboratory of Analysis and Detection for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and…
  • Key Laboratory of Cultivation and High-value Utilization of Marine Organisms in Fujian Province, Fisheries Research Institute of Fujian, Xiamen, 361013, China.
  • College of Biological Science and Engineering, Fuzhou University, Fuzhou, Fujian, 350116, China.
  • MOE Key Laboratory of Analysis and Detection for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 3…

Förderung

  • University of Newcastle Australia
  • National Natural Science Foundation of China

Zitieren

APA

Luo, F., Zhan, L., Deng, Y., Qiao, K., Pan, N., Weng, Z., Lin, C., Qiu, B., & Lin, Z. (2023). Oxygen-induced dual-signal point-of-care testing aptasensor for aflatoxin B1 detection using platinum nanoparticle catalysis in visual fluorometry and gravimetry. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2023.341544

Vancouver

Luo F, Zhan L, Deng Y, Qiao K, Pan N, Weng Z, et al. Oxygen-induced dual-signal point-of-care testing aptasensor for aflatoxin B1 detection using platinum nanoparticle catalysis in visual fluorometry and gravimetry. Analytica Chimica Acta. 2023. doi:10.1016/j.aca.2023.341544

BibTeX
@article{Luo2023,
  author = {Luo, Fang and Zhan, Linxiu and Deng, Ye and Qiao, Kun and Pan, Nan and Weng, Zuquan and Lin, Cuiying and Qiu, Bin and Lin, Zhenyu},
  title = {Oxygen-induced dual-signal point-of-care testing aptasensor for aflatoxin B1 detection using platinum nanoparticle catalysis in visual fluorometry and gravimetry},
  journal = {Analytica Chimica Acta},
  year = {2023},
  doi = {10.1016/j.aca.2023.341544}
}
Kostenlos starten →