EUVIMEDEUVIMED entdecken
Crossref

A novel dual-signal output strategy for POCT of CEA based on a smartphone electrochemical aptasensing platform

Shan-Shan Shi, Xiao-Jian Li, Rong-Na Ma, Lei Shang, Wei Zhang, Huai-Qing Zhao, Li-Ping Jia, Huai-Sheng Wang

Microchimica Acta · 2024

DOI: 10.1007/s00604-024-06493-z ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Shan-Shan Shi und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shandong, 250022, People's Republic of China. Hauptthemen laut MEDLINE: Carcinoembryonic Antigen, Aptamers, Nucleotide, Smartphone, Electrochemical Techniques. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Natural Science Foundation of Shandong Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A smartphone-based electrochemical aptasensing platform was developed for the point-of-care testing (POCT) of carcinoembryonic antigen (CEA) based on the ferrocene (Fc) and PdPt@PCN-224 dual-signal labeled strategy. The prepared PdPt@PCN-224 nanocomposite showed a strong catalytic property for the reduction of H2O2. Phosphate group-labeled aptamer could capture PdPt@PCN-224 by Zr-O-P bonds to form PdPt@PCN-224-P-Apt. Therefore, a dual signal labeled probe was formed by the hybridization between Fc-DNA and PdPt@PCN-224-P-Apt. The presence of CEA forced PdPt@PCN-224-P-Apt to leave the electrode surface due to the specific affinity, leading to the decrease of the reduction current of H2O2. At the same time, the Fc-DNA strand changed to hairpin structure, which made Fc closer to the electrode and resulted in the increase of the oxidation current of Fc. Thus, CEA can be accurately determined through both signals: the decrease of H2O2 reduction current and the increase of Fc oxidation current, which could avoid the false positive signal. Under the optimal conditions, the prepared aptasensor exhibited a wide linear range from 1 pg·mL-1 to 100 ng·mL-1 and low detection limits of 0.98 pg·mL-1 and 0.27 pg·mL-1 with Fc and PdPt@PCN-224 as signal labels, respectively. The aptasensor developed in this study has successfully demonstrated its capability to detect CEA in real human serum samples. These findings suggest that the proposed sensing platform will hold great potential for clinical tumor diagnosis and monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carcinoembryonic AntigenAptamers, NucleotideSmartphoneElectrochemical TechniquesBiosensing TechniquesHydrogen PeroxideLimit of DetectionPalladiumPoint-of-Care TestingFerrous CompoundsHumansMetallocenesPlatinum

Stichwörter der Autor:innen

Differential pulse voltammetryDual-signal output strategyPOCTPdPt@PCN-224

Substanzen

Carcinoembryonic AntigenAptamers, NucleotideHydrogen PeroxidePalladiumFerrous CompoundsferroceneMetallocenesPlatinum

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shandong, 250022, People's Republic of China.
  • College of Chemistry and Chemical Engineering, Liaocheng University, Liaocheng, 252000, People's Republic of China.
  • School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shandong, 250022, People's Republic of China. chm_zhaohq@ujn.edu.cn.
  • College of Chemistry and Chemical Engineering, Liaocheng University, Liaocheng, 252000, People's Republic of China. jialiping@lcu.edu.cn.
  • College of Chemistry and Chemical Engineering, Liaocheng University, Liaocheng, 252000, People's Republic of China. hswang@lcu.edu.cn.

Förderung

  • Natural Science Foundation of Shandong Province
  • National Natural Science Foundation of China

Zitieren

APA

Shi, S. S., Li, X. J., Ma, R. N., Shang, L., Zhang, W., Zhao, H. Q., Jia, L. P., & Wang, H. S. (2024). A novel dual-signal output strategy for POCT of CEA based on a smartphone electrochemical aptasensing platform. Microchimica Acta. https://doi.org/10.1007/s00604-024-06493-z

Vancouver

Shi SS, Li XJ, Ma RN, Shang L, Zhang W, Zhao HQ, et al. A novel dual-signal output strategy for POCT of CEA based on a smartphone electrochemical aptasensing platform. Microchimica Acta. 2024. doi:10.1007/s00604-024-06493-z

BibTeX
@article{Shi2024,
  author = {Shi, Shan-Shan and Li, Xiao-Jian and Ma, Rong-Na and Shang, Lei and Zhang, Wei and Zhao, Huai-Qing and Jia, Li-Ping and Wang, Huai-Sheng},
  title = {A novel dual-signal output strategy for POCT of CEA based on a smartphone electrochemical aptasensing platform},
  journal = {Microchimica Acta},
  year = {2024},
  doi = {10.1007/s00604-024-06493-z}
}
Kostenlos starten →