EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

HF-MMLLE using natural deep eutectic solvents for determination of potential lung cancer biomarkers in urine

Amanda Vitória Santos, Camila Will, Francielle Crocetta Turazzi, Lucas Morés, Eduardo Carasek

Analytical Biochemistry · 2027-01 · 720 · 116253

DOI: 10.1016/j.ab.2026.116253 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Biochemistry, 2027-01. Verfasst von Amanda Vitória Santos und 4 weiteren Autor:innen. Beteiligte Einrichtung: Chemistry Department, Federal University of Santa Catarina (UFSC), Eng. Agronômico Andrei Cristian Ferreira, s/n, Florianópolis, SC, 88040-900, Brazi…. Hauptthemen laut MEDLINE: Aldehydes, Deep Eutectic Solvents, Biomarkers, Tumor, Liquid-Liquid Extraction. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Conselho Nacional de Desenvolvimento Científico e Tecnológico, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Fundação de Amparo à Pesquisa e Inovação do Estado de Santa Catarina.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work expands the use of a natural deep eutectic solvent (NADES) as an alternative extractor solvent for organic solvents. Hollow fiber-microporous membrane liquid-liquid extraction (HF-MMLLE) coupled to the 96-well plate system was employed for the determination of hexanal and heptanal in urine samples. The NADES used as the extractor solvent consisted of dodecanoic acid:hexanoic acid (1:3, molar ratio). Method optimization was carried out using univariate and multivariate approaches. Extractions were performed for 60 min, followed by 30 min of derivatization reaction with 2,4-dinitrophenylhydrazine (DNPH) and buffer solution in 1:30 M ratio (aldehyde:DNPH). The sample pH was maintained at 6.0. Desorption was performed using a mixture of acetonitrile:methanol (1:1, v/v) for 5 min. The method achieved an average throughput of approximately 1 min preparation time per sample, considering the parallel processing of 96 samples. The analytical parameters were evaluated through calibration curves with coefficients of determination (R2) of 0.9973 for hexanal and 0.9935 for heptanal. The limits of quantification (LOQ) were 100 μg L-1 for hexanal and heptanal. Intraday and interday precision ranged from 9% to 20% and 15% to 22%, respectively. The relative recovery varied from 61.8% to 118.6%. The proposed method integrates the advantages of NADES with membrane-based extraction, resulting in a more sustainable, low-solvent and high-throughput analytical strategy for the determination of biomarkers of aldehydes in urine. The implementation of a 96-well plate configuration enables the simultaneous processing of multiple samples, improving analytical sample throughput and operational efficiency.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AldehydesDeep Eutectic SolventsBiomarkers, TumorLiquid-Liquid ExtractionHumansSolventsLimit of Detection

Stichwörter der Autor:innen

HeptanalHexanalHollow fiber-membrane microporous liquid-liquid extractionLiquid chromatographyNatural deep eutectic solvent

Substanzen

AldehydesDeep Eutectic Solventsheptanaln-hexanalBiomarkers, TumorSolvents

Autor:innen und Institutionen

  • Chemistry Department, Federal University of Santa Catarina (UFSC), Eng. Agronômico Andrei Cristian Ferreira, s/n, Florianópolis, SC, 88040-900, Brazil.
  • Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Eng. Agronômico Andrei Cristian Ferreira, s/n, Florianópolis, 88040-900, Brazil.
  • Chemistry Department, Federal University of Santa Catarina (UFSC), Eng. Agronômico Andrei Cristian Ferreira, s/n, Florianópolis, SC, 88040-900, Brazil. Electronic address: eduardo.carasek@ufsc.br.

Förderung

  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
  • Fundação de Amparo à Pesquisa e Inovação do Estado de Santa Catarina

Zitieren

APA

Santos, A. V., Will, C., Turazzi, F. C., Morés, L., & Carasek, E. (2027). HF-MMLLE using natural deep eutectic solvents for determination of potential lung cancer biomarkers in urine. Analytical Biochemistry, 720, 116253. https://doi.org/10.1016/j.ab.2026.116253

Vancouver

Santos AV, Will C, Turazzi FC, Morés L, Carasek E. HF-MMLLE using natural deep eutectic solvents for determination of potential lung cancer biomarkers in urine. Analytical Biochemistry. 2027;720:116253. doi:10.1016/j.ab.2026.116253

BibTeX
@article{Santos2027,
  author = {Santos, Amanda Vitória and Will, Camila and Turazzi, Francielle Crocetta and Morés, Lucas and Carasek, Eduardo},
  title = {HF-MMLLE using natural deep eutectic solvents for determination of potential lung cancer biomarkers in urine},
  journal = {Analytical Biochemistry},
  year = {2027},
  volume = {720},
  pages = {116253},
  doi = {10.1016/j.ab.2026.116253}
}
Kostenlos starten →