EUVIMEDEUVIMED entdecken
Crossref

Rapid and accurate detection of urinary iodine by single crystal silver iodide sensor

Jianmin Yang, Kai Tang, Shuyan Xiong, Liang Shi, Aidong Tang

Analytical Biochemistry · 2025-11 · 706 · 115939

DOI: 10.1016/j.ab.2025.115939 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Biochemistry, 2025-11. Verfasst von Jianmin Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China. Hauptthemen laut MEDLINE: Iodides, Iodine, Silver Compounds. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Iodine deficiency or excess impacts thyroid health, necessitating accurate urinary iodine monitoring. However, existing detection methods face challenges including complicated sample handling, poor anti-interference ability, and the detection range does not cover the range of human urinary iodine concentration. Conventional iodide ion-selective electrode is based on polycrystalline membranes, which has high detection limit and is susceptible to chloride ion interference. It is also not suitable for accurate detection of human urinary iodine. In this study, we introduced a single-crystal AgI electrode for rapid and interference-free detection of urinary iodine. The dense (220) crystal plane of the single-crystal AgI electrode provided excellent selectivity and sensitivity, with a detection limit as low as 59 μg L-1 and good linearity in the range of 100-1000 μg L-1. This fully covers the optimal range of urinary iodine concentrations recommended by the World Health Organization (100-500 μg L-1). Importantly, the single-crystal AgI electrode has excellent resistance to chloride interference, which is a significant improvement over conventional polycrystallaline iodide ion-selective electrodes. Our results show that the electrode has excellent precision, stability and accuracy without interference from common urine ions. This work addresses the limitations of existing methods and provides a rapid, inexpensive and reliable method for urinary iodine testing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IodidesIodineSilver CompoundsHumansLimit of DetectionElectrodesElectrochemical TechniquesIon-Selective Electrodes

Stichwörter der Autor:innen

DetectionSensorSilver iodideSingle crystalUrinary iodine

Substanzen

IodidesIodineSilver Compoundssilver iodide

Autor:innen und Institutionen

  • College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China.
  • College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China. Electronic address: adtang@csu.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Yang, J., Tang, K., Xiong, S., Shi, L., & Tang, A. (2025). Rapid and accurate detection of urinary iodine by single crystal silver iodide sensor. Analytical Biochemistry, 706, 115939. https://doi.org/10.1016/j.ab.2025.115939

Vancouver

Yang J, Tang K, Xiong S, Shi L, Tang A. Rapid and accurate detection of urinary iodine by single crystal silver iodide sensor. Analytical Biochemistry. 2025;706:115939. doi:10.1016/j.ab.2025.115939

BibTeX
@article{Yang2025,
  author = {Yang, Jianmin and Tang, Kai and Xiong, Shuyan and Shi, Liang and Tang, Aidong},
  title = {Rapid and accurate detection of urinary iodine by single crystal silver iodide sensor},
  journal = {Analytical Biochemistry},
  year = {2025},
  volume = {706},
  pages = {115939},
  doi = {10.1016/j.ab.2025.115939}
}
Kostenlos starten →