EUVIMEDEUVIMED entdecken
Crossref

Electrochemical detection of myoglobin using an ultrasensitive label-free sensor derived from cubic-ZIF67@Au-rGOF-NH2 composite of MOF and GOF

Chunyan Wu, Wendi Mu, Fangfang Wu, Hongmin Gao, Xinshui Ren, Jing Feng, Men Miao, Hehua Zhang, Dong Chang, Hongzhi Pan

Analytical Biochemistry · 2024

DOI: 10.1016/j.ab.2024.115571 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Biochemistry, 2024. Verfasst von Chunyan Wu und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Health Sciences and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, People's Republic of China; Collabora…. Hauptthemen laut MEDLINE: Myoglobin, Electrochemical Techniques, Graphite, Metal-Organic Frameworks. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Markers of myocardial injury, such as myoglobin (Mb), are substances swiftly released into the peripheral bloodstream upon myocardial cell injury or altered cardiac activity. During the onset of acute myocardial infarction, patients experience a significant surge in serum Mb levels. Given this, precise detection of Mb is essential, necessitating the development of innovative assays to optimize detection capabilities. This study introduces the synthesis of a three-dimensional hierarchical nanocomposite, Cubic-ZIF67@Au-rGOF-NH2, utilizing aminated reduced graphene oxide and zeolite imidazolium ester framework-67 (ZIF67) as foundational structures. Notably, this novel material, applied in a label-free electrochemical immunosensor, presents a groundbreaking approach for detecting myocardial injury markers. Experimental outcomes revealed ZIF67 and AuNPs exhibit enhanced affinity and growth on the 3D-rGOF-NH2 matrix, thus amplifying electrical conductivity while preserving the inherent electrochemical attributes of ZIF67. As a result, the Cubic-ZIF67@Au-rGOF-NH2 label-free electrochemical immunosensor exhibited a broad detection range and high sensitivity for Mb. The derived standard curve was ΔIp = 16.67552lgC+275.245 (R = 0.993) with a detection threshold of 3.47 fg/ml. Moreover, recoveries of standards spiked into samples ranged between 96.3% and 108.7%. Importantly, the devised immunosensor retained notable selectivity against non-target proteins, proving its potential clinical utility based on exemplary sample analysis performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MyoglobinElectrochemical TechniquesGraphiteMetal-Organic FrameworksGoldHumansBiosensing TechniquesNanocompositesZeolitesImidazolesLimit of DetectionMetal Nanoparticles

Stichwörter der Autor:innen

3D-rGOF-NH(2)Cubic-ZIF67@Au-rGOF-NH(2)ImmunosensorLabel-free electrochemical sensorMyoglobin (Mb)ZIF67

Substanzen

MyoglobinGraphiteMetal-Organic FrameworksGoldgraphene oxideZeolitesImidazoles

Autor:innen und Institutionen

  • School of Health Sciences and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, People's Republic of China; Collaborative Research Center, Shanghai University of Medicine and Health Scien…
  • Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai, 201318, People's Republic of China.
  • Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai, 201318, People's Republic of China; Shanghai University of Medicine and Health Sciences, Shanghai University of Traditional C…
  • Department of Laboratory Medicine, Shanghai Pudong Hospital, Shanghai, 201399, People's Republic of China. Electronic address: changdongydy@163.com.

Zitieren

APA

Wu, C., Mu, W., Wu, F., Gao, H., Ren, X., Feng, J., Miao, M., Zhang, H., Chang, D., & Pan, H. (2024). Electrochemical detection of myoglobin using an ultrasensitive label-free sensor derived from cubic-ZIF67@Au-rGOF-NH2 composite of MOF and GOF. Analytical Biochemistry. https://doi.org/10.1016/j.ab.2024.115571

Vancouver

Wu C, Mu W, Wu F, Gao H, Ren X, Feng J, et al. Electrochemical detection of myoglobin using an ultrasensitive label-free sensor derived from cubic-ZIF67@Au-rGOF-NH2 composite of MOF and GOF. Analytical Biochemistry. 2024. doi:10.1016/j.ab.2024.115571