Abstract (Originalsprache)

Background/objective Novel resin materials for direct 3D printing of clear aligners have been recently introduced. The purpose of this study was to assess the water absorption over a time of 11 days in samples printed with different 3D printing settings when they are immersed in a liquid medium, and their possible leaching.

Methods

Samples were directly 3D printed, post-cured, and placed inside test tubes with artificial saliva in a thermostatic bath at 37 °C. The weight variation of each sample was assessed using a precision balance 5′, 10′, 15′, 30′, 1 h, 2 h, and 4 h after immersion and then twice per day over 11 days. Then, a Fourier-transform infrared spectroscopy–attenuated total reflection (FTIR-ATR) spectrophotometer was used to evaluate the possible release of materials into the artificial saliva.

Results

A significant longitudinal difference was found in the relative weight increase of the samples ( p < 0.001). The maximum percentage weight increase of the samples in the first 4 h was 3.6%. No significant differences among groups in weight variation in the first 4 h were found. Weight variation shows an increasing trend with local variations according to the resin.

Conclusion

Under the simplified experimental conditions used in this study, no clear FTIR-detectable leaching was observed. However, the absence of detectable FTIR signals should not be interpreted as the absence of trace-level leachables. Further studies, under patient-dependent conditions, are needed in order to fully understand the clinical eventuality of leaching.

Zitieren

APA

Drago, S., Lagazzo, A., Finocchio, E., Pastore, E., Maria, M., & Migliorati, M. (2026). Water absorption and leaching inside artificial saliva of resins for 3D direct printing of orthodontic aligners. Digital and Aligner Orthodontics. https://doi.org/10.1007/s44525-026-00012-6

Vancouver

Drago S, Lagazzo A, Finocchio E, Pastore E, Maria M, Migliorati M. Water absorption and leaching inside artificial saliva of resins for 3D direct printing of orthodontic aligners. Digital and Aligner Orthodontics. 2026. doi:10.1007/s44525-026-00012-6

BibTeX
@article{Drago2026,
  author = {Drago, Sara and Lagazzo, Alberto and Finocchio, Elisabetta and Pastore, Eleonora and Maria, Menini and Migliorati, Marco},
  title = {Water absorption and leaching inside artificial saliva of resins for 3D direct printing of orthodontic aligners},
  journal = {Digital and Aligner Orthodontics},
  year = {2026},
  doi = {10.1007/s44525-026-00012-6}
}
Kostenlos starten →