Chinese Reading Performance with Toric Versus Spherical Equivalent Soft Contact Lenses: A Participant-Masked Randomised Crossover Eye-Tracking Study
Ophthalmic and Physiological Optics · 2026
DOI: 10.1007/s44402-026-00136-x ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Ophthalmic and Physiological Optics, 2026. Verfasst von Chin-Te Huang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung, Taiwan, ROC. Hauptthemen laut MEDLINE: Astigmatism, Contact Lenses, Hydrophilic, Eye Movements, Eye-Tracking Technology. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
PURPOSE: To evaluate the impact of toric versus spherical equivalent contact lenses on visual acuity and eye-movement-based reading performance in young adults with low-to-moderate astigmatism, using Chinese reading passages to reflect real-world tasks. METHODS: A participant-masked, randomised, two-period crossover study was conducted in 28 young adults (aged 18-35 years) with low-to-moderate refractive astigmatism (-0.75 to -2.00 dioptre cylinder [DC]). Participants wore toric and spherical equivalent daily disposable soft contact lenses (SCLs) for 1 week each, in random order. Binocular distance, intermediate and near visual acuity were measured and reading performance was assessed during silent reading of standardised Chinese passages using the EyeLink 1000 Plus. Key metrics included reading speed, fixation count, fixation per minute (fpm), fixation per word (fpw), saccade characteristics and regressions. RESULTS: Toric lenses significantly improved binocular intermediate visual acuity at 66 cm (-0.11 ± 0.07 vs. -0.07 ± 0.08 logMAR, p = 0.04) and reading speed (345.37 ± 122.41 vs. 322.49 ± 130.65 characters per minute [cpm], p = 0.03), compared with spherical equivalent lenses. Additionally, toric correction was associated with more efficient eye-movement behaviour, including fewer fixations per word, fewer total fixations, fewer total saccades and fewer regressions (all p < 0.05). CONCLUSION: Toric SCLs improved intermediate visual acuity and Chinese reading performance relative to spherical equivalent correction in young adults with low-to-moderate astigmatism. These findings support the functional benefit of full astigmatic correction for visually demanding mid-range reading tasks.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung, Taiwan, ROC.
- Department of Ophthalmology, School of Medicine, College of Medicine, Chung Shan Medical University, Taichung, Taiwan, ROC.
- Department of Optometry, College of Medical Science and Technology, Chung Shan Medical University, Taichung, Taiwan, ROC.
- Department of Optometry, University of Kang Ning, Taipei, Taiwan, ROC.
- Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung, Taiwan, ROC. hanying@csmu.edu.tw.
- Department of Optometry, College of Medical Science and Technology, Chung Shan Medical University, Taichung, Taiwan, ROC. hanying@csmu.edu.tw.
Zitieren
APA
Huang, C. T., Lin, J. W., Tsung, W. C., & Sun, H. Y. (2026). Chinese Reading Performance with Toric Versus Spherical Equivalent Soft Contact Lenses: A Participant-Masked Randomised Crossover Eye-Tracking Study. Ophthalmic and Physiological Optics. https://doi.org/10.1007/s44402-026-00136-x
Vancouver
Huang CT, Lin JW, Tsung WC, Sun HY. Chinese Reading Performance with Toric Versus Spherical Equivalent Soft Contact Lenses: A Participant-Masked Randomised Crossover Eye-Tracking Study. Ophthalmic and Physiological Optics. 2026. doi:10.1007/s44402-026-00136-x
BibTeX
@article{Huang2026,
author = {Huang, Chin-Te and Lin, Jou-Wen and Tsung, Wan-Yun Connie and Sun, Han-Yin},
title = {Chinese Reading Performance with Toric Versus Spherical Equivalent Soft Contact Lenses: A Participant-Masked Randomised Crossover Eye-Tracking Study},
journal = {Ophthalmic and Physiological Optics},
year = {2026},
doi = {10.1007/s44402-026-00136-x}
}
EUVIMED