Improving the surface quality of “M” shape-link 316L stent by electrochemical polishing and investigating its mechanical properties

Hezong Li, Luhan Li, Xiaoman Guo, Chen Pan

Surface Science and Technology · 2026-12 · 4 (1)

DOI: 10.1007/s44251-026-00145-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Surface Science and Technology, online erschienen am 23.05.2026. Verfasst von Hezong Li und 3 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Department of Education of Hebei Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Additive manufacturing of metal stents (such as selective laser melting technology) may result in a relatively high surface roughness, which significantly affects the mechanical properties. To address the surface quality issue, this study employed electrochemical polishing technology to reduce the surface roughness of "M" shape-link 316L stent manufactured by selective laser melting technology, and evaluated the mechanical properties. The results showed that electrochemical polishing effectively removed the residual powder particles adhering to the surface of stent and the irregular surface protrusions formed during the manufacturing process, thereby reducing the surface roughness of 316L stents to less than 5 µm. Electrochemical polishing decreased the radial force of stents from 31.68 N to 19.71 N, but improved the axial compliance and flexibility. Its bending stiffness (10 N/mm) was reduced by 16 N/mm compared to 26 N/mm before polishing. The maximum load at the maximum deformation of 2.5 mm decreased by 4.8 N, thereby improving the compliance. Additionally, the maximum bending force (5.8 N) decreased by only 8.37 N, indicating that its resistance to bending fracture was sufficiently strong. Meanwhile, electrochemical polishing did not reduce the fatigue life of stents. After subjecting the polished stent to 1 × 10⁶ cycles of accelerated cyclic loading, the stent still retained its initial structural integrity, while both its peak pressure and overall pressure decreased, the specific reduction was only 12.5%. In conclusion, after electrochemical polishing, although a certain degree of stent rigidity was sacrificed, good flexibility and potential long-term implant durability were achieved.

Förderung

  • Department of Education of Hebei Province

Zitieren

APA

Li, H., Li, L., Guo, X., & Pan, C. (2026). Improving the surface quality of “M” shape-link 316L stent by electrochemical polishing and investigating its mechanical properties. Surface Science and Technology, 4(1). https://doi.org/10.1007/s44251-026-00145-5

Vancouver

Li H, Li L, Guo X, Pan C. Improving the surface quality of “M” shape-link 316L stent by electrochemical polishing and investigating its mechanical properties. Surface Science and Technology. 2026;4(1). doi:10.1007/s44251-026-00145-5

BibTeX
@article{Li2026,
  author = {Li, Hezong and Li, Luhan and Guo, Xiaoman and Pan, Chen},
  title = {Improving the surface quality of “M” shape-link 316L stent by electrochemical polishing and investigating its mechanical properties},
  journal = {Surface Science and Technology},
  year = {2026},
  volume = {4},
  number = {1},
  doi = {10.1007/s44251-026-00145-5}
}
Kostenlos starten →