EUVIMEDEUVIMED entdecken
Crossref

A label-free electrochemical biosensor based on rGO/Ppy nanocomposite for detection of Herpes simplex virus type 1

Hamed Sadegh Mazji, Fatemeh Zeydi, Amir Hossein Esfandiari, Ehsan Aryan, Seyed Abdolrahim Rezaee, Seyedeh Belin Tavakoly Sany, Zahra Meshkat, Behnaz Hatamluyi

Analytical Sciences · 2025-07 · 41 (7) · 997-1005

DOI: 10.1007/s44211-025-00779-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Sciences, online erschienen am 19.05.2025. Verfasst von Hamed Sadegh Mazji und 7 weiteren Autor:innen. Beteiligte Einrichtung: Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran. Hauptthemen laut MEDLINE: Biosensing Techniques, Herpesvirus 1, Human, Nanocomposites, Graphite. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Mashhad University of Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The herpes simplex virus type 1 (HSV-1) is a prevalent herpes virus found in many regions worldwide, and it infects only humans as its natural hosts. These viruses cause a wide range of acute, latent, and chronic infections in humans, as the virus can cause latent infections as well as diseases such as primary and recurrent oropharyngeal disease, primary and recurrent genital disease, and herpes simplex infection. Therefore, a fast response, cost-effective, sensitive, and selective detection method for HSV-1 is much needed. Here, we present an electrochemical biosensor that is sensitive and selective for the accurate measurement of HSV-1. The glassy carbon electrode was coated with a reduced graphene oxide and polypyrrole nanocomposite (rGO/Ppy-NCs) for modification. The next step involved linking a specific antisense single-stranded DNA oligonucleotide for HSV-1 to the rGO/Ppy-NCs through a π-stacking interaction. The process of DNA hybridization was assessed through the measurement of changes in the free guanine peak current with changing ssDNA target concentrations by employing the method called differential pulse voltammetry (DPV). This biosensor showed a consistent response to synthetic ssDNA target, ranging from 1.0 × 10-15 to 1.0 × 10-11 M, with a detection limit of 0.83 fM. The biosensor's performance was put to the test using a cell culture sample positive for HSV-1, a positive HTLV-1 sample, and a PCR-confirmed negative sample. The obtained results exhibited excellent detection potential of the proposed biosensor as a sensitive and specific biosensing system.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesHerpesvirus 1, HumanNanocompositesGraphitePolymersElectrochemical TechniquesPyrrolesHumansElectrodesLimit of Detection

Stichwörter der Autor:innen

Herpes simplex virus type 1DNA biosensorPolypyrroleReduced graphene oxide

Substanzen

polypyrroleGraphitePolymersgraphene oxidePyrroles

Autor:innen und Institutionen

  • Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Immunology Research Center, Inflammation and Inflammatory Diseases Division, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Social Determinants of Health Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Department of Health, Safety, Environment Management, School of Health, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran. meshkatz@mums.ac.ir.
  • Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran. Behnazhatamluyi@gmail.com.

Förderung

  • Mashhad University of Medical Sciences

Zitieren

APA

Mazji, H. S., Zeydi, F., Esfandiari, A. H., Aryan, E., Rezaee, S. A., Sany, S. B. T., Meshkat, Z., & Hatamluyi, B. (2025). A label-free electrochemical biosensor based on rGO/Ppy nanocomposite for detection of Herpes simplex virus type 1. Analytical Sciences, 41(7), 997-1005. https://doi.org/10.1007/s44211-025-00779-9

Vancouver

Mazji HS, Zeydi F, Esfandiari AH, Aryan E, Rezaee SA, Sany SBT, et al. A label-free electrochemical biosensor based on rGO/Ppy nanocomposite for detection of Herpes simplex virus type 1. Analytical Sciences. 2025;41(7):997-1005. doi:10.1007/s44211-025-00779-9

BibTeX
@article{Mazji2025,
  author = {Mazji, Hamed Sadegh and Zeydi, Fatemeh and Esfandiari, Amir Hossein and Aryan, Ehsan and Rezaee, Seyed Abdolrahim and Sany, Seyedeh Belin Tavakoly and Meshkat, Zahra and Hatamluyi, Behnaz},
  title = {A label-free electrochemical biosensor based on rGO/Ppy nanocomposite for detection of Herpes simplex virus type 1},
  journal = {Analytical Sciences},
  year = {2025},
  volume = {41},
  number = {7},
  pages = {997--1005},
  doi = {10.1007/s44211-025-00779-9}
}
Kostenlos starten →