Fachartikel in der Zeitschrift Analytical Sciences, 2024. Verfasst von Chaowen Zheng und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Mechanics, Guangxi University, 100 East University Road, Nanning, 530004, Guangxi, China. Hauptthemen laut MEDLINE: alpha-Fetoproteins, Lasers. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Innovative Research Group Project of the National Natural Science Foundation of China, Guangxi Bagui Scholars Project, Guangxi University Innovation Development Doubling Plan project.
Abstract (Originalsprache)
Alpha-fetoprotein (AFP), commonly employed for early diagnosis of liver cancer, serves as a biomarker for cancer screening and diagnosis. Combining the high sensitivity and specificity of fluorescence immunoassay (FIA), developing a low-cost and efficient immunoassay system for AFP detection holds significant importance in disease diagnosis. In this work, we developed a miniaturized oblique laser-induced fluorescence (LIF) immunoassay system, coupled with a microfluidic PMMA/paper hybrid chip, for rapid detection of AFP. The system employed an avalanche photodiode (APD) as the detector, and implemented multi-level filtering in the excitation light channel using the dichroic mirror and optical trap. At first, we employed the Savitzky-Golay filter and baseline off-set elimination methods to denoise and normalize the original data. Then the cutoff frequency of the low-pass filter and the reverse voltage of the APD were optimized to enhance the detection sensitivity of the system. Furthermore, the effect of laser power on the fluorescence excitation efficiency was investigated, and the sampling time during the scanning process was optimized. Finally, a four-parameter logistic (4PL) model was utilized to establish the concentration-response equation for AFP. The system was capable of detecting concentrations of AFP standard solution within the range of 1-500 ng/mL, with a detection limit of 0.8 ng/mL. The entire immunoassay process could be completed within 15 min. It has an excellent potential for applications in low-cost portable diagnostic instruments for the rapid detection of biomarkers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Mechanics, Guangxi University, 100 East University Road, Nanning, 530004, Guangxi, China.
- College of Medical, Guangxi University, 100 East University Road, Nanning, 530004, Guangxi, China.
- College of Computer and Electronic Information, Guangxi University, 100 East University Road, Nanning, 530004, Guangxi, China. cmsun@gxu.edu.cn.
Förderung
- Innovative Research Group Project of the National Natural Science Foundation of China
- Guangxi Bagui Scholars Project
- Guangxi University Innovation Development Doubling Plan project
- Science and Technology Major Project of Guangxi
Zitieren
APA
Zheng, C., Dai, P., You, H., Xian, Z., Su, W., Wu, S., Xing, D., & Sun, C. (2024). A compact microfluidic laser-induced fluorescence immunoassay system using avalanche photodiode for rapid detection of alpha-fetoprotein. Analytical Sciences. https://doi.org/10.1007/s44211-024-00553-3
Vancouver
Zheng C, Dai P, You H, Xian Z, Su W, Wu S, et al. A compact microfluidic laser-induced fluorescence immunoassay system using avalanche photodiode for rapid detection of alpha-fetoprotein. Analytical Sciences. 2024. doi:10.1007/s44211-024-00553-3
BibTeX
@article{Zheng2024,
author = {Zheng, Chaowen and Dai, Peng and You, Hui and Xian, Zhaokun and Su, Wenyun and Wu, Shixiong and Xing, Dong and Sun, Cuimin},
title = {A compact microfluidic laser-induced fluorescence immunoassay system using avalanche photodiode for rapid detection of alpha-fetoprotein},
journal = {Analytical Sciences},
year = {2024},
doi = {10.1007/s44211-024-00553-3}
}
EUVIMED