Sacral Alar-Iliac (SAI) screw diameter is not associated with pelvic fixation failure for neuromuscular scoliosis patients
Spine Deformity · 2025
DOI: 10.1007/s43390-025-01044-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spine Deformity, 2025. Verfasst von Tyler A Tetreault und 5 weiteren Autor:innen. Beteiligte Einrichtung: Jackie and Gene Autry Children's Orthopedic Center, Children's Hospital Los Angeles, 4650 Sunset Blvd, MS69, Los Angeles, CA, 90027, USA. ttetreault@…. Hauptthemen laut MEDLINE: Scoliosis, Spinal Fusion, Bone Screws, Sacrum. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Southern California.
Abstract (Originalsprache)
Purpose
Determine if Sacral Alar-Iliac (SAI) screw diameter is associated with pelvic fixation failure in pediatric patients with neuromuscular scoliosis (NMS) treated with posterior spinal fusion (PSF).
Methods
NMS patients from a single institution who underwent PSF with bilateral SAI screw fixation from 2010 to 2021 were retrospectively reviewed. Clinical parameters, SAI screw sizes, and radiographic outcomes were analyzed. Patients with greater or less than two SAI screws, > 21 years old, or with < 2 years of radiographic follow-up were excluded.
Results
142 patients had 284 SAI screws placed. Mean(± SD) age was 13.6 ± 2.7 years. Preoperative curve magnitude averaged 84.3 ± 29.1°. Mean patient weight was 36.4 ± 14.1kg and BMI was 18 ± 5.1. Radiographic follow-up averaged 4.6 ± 2.0 years. Most screws (234/284,82.4%) were < 8.5 mm and 7.5 mm screws were most frequently used (158/248,55.6%). Mean screw diameter was 7.4 ± 0.7 mm. Patients with greater age, weight, and BMI trended towards larger screws. Three patients had five screw complications (1 screw fracture and 4 set screw dislodgments). One screw fracture (1/284,0.4%;7.5 mm diameter) and contralateral set screw dislodgement occurred in a patient at 14 months but was not revised. One patient who had bilateral set screws dislodge 3 months after PSF underwent revision. The remaining patient was asymptomatic and was observed. Screw diameter was not associated with risk of postoperative complications ( p = 0.245).
Conclusion
SAI screw fracture is rare after PSF in pediatric patients with NMS. Contrary to pelvic fixation in adults, smaller diameter SAI screws, which may be optimal in patients with smaller anatomy, were not associated with increased risk of screw failure. Level of evidence III.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Jackie and Gene Autry Children's Orthopedic Center, Children's Hospital Los Angeles, 4650 Sunset Blvd, MS69, Los Angeles, CA, 90027, USA. ttetreault@chla.usc.edu.
- Jackie and Gene Autry Children's Orthopedic Center, Children's Hospital Los Angeles, 4650 Sunset Blvd, MS69, Los Angeles, CA, 90027, USA.
Förderung
- University of Southern California
Zitieren
APA
Tetreault, T. A., Myers, A. Y., Valenzuela-Moss, J., Wren, T. A. L., Heffernan, M. J., & Andras, L. M. (2025). Sacral Alar-Iliac (SAI) screw diameter is not associated with pelvic fixation failure for neuromuscular scoliosis patients. Spine Deformity. https://doi.org/10.1007/s43390-025-01044-9
Vancouver
Tetreault TA, Myers AY, Valenzuela-Moss J, Wren TAL, Heffernan MJ, Andras LM. Sacral Alar-Iliac (SAI) screw diameter is not associated with pelvic fixation failure for neuromuscular scoliosis patients. Spine Deformity. 2025. doi:10.1007/s43390-025-01044-9
BibTeX
@article{Tetreault2025,
author = {Tetreault, Tyler A and Myers, Annika Y and Valenzuela-Moss, Jaqueline and Wren, Tishya A L and Heffernan, Michael J and Andras, Lindsay M},
title = {Sacral Alar-Iliac (SAI) screw diameter is not associated with pelvic fixation failure for neuromuscular scoliosis patients},
journal = {Spine Deformity},
year = {2025},
doi = {10.1007/s43390-025-01044-9}
}