Reuse and remanufacturing of insulated glass units
Glass Structures & Engineering · 2024-12 · 9 (3-4) · 339-356
DOI: 10.1007/s40940-024-00276-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Glass Structures & Engineering, online erschienen am 27.08.2024. Verfasst von Martien Teich und 4 weiteren Autor:innen. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hochschule für angewandte Wissenschaften München.
Abstract (Originalsprache)
Many office and residential buildings in Europe need to be renovated in the near future to meet current energy efficiency requirements. This often comes down to updating the insulation performance of the building envelope including the windows. Most “old” windows consist of a frame and a double insulated glass unit (IGU) or even monolithic glass panes – typically without any low-e coating. These non-coated double glazings have a U g -value of 2.7 W/m 2 K (single glazing even 5.2 W/m 2 K). Modern coated triple glazed IGUs provide U g -values of up to 0.5 W/m 2 K. This paper deals with the question of how old insulating glass units can be re manufactured to match the state of the art in terms of the energy efficiency. For this purpose, dismounted IGUs from the 1980s are used. After analyzing the remaining functionality, the double IGUs are disassembled. The single glass pane is cleaned, and the old edge sealing is removed. The old glass pane is combined with a new coated low-e glass and a spacer system to form a new upgraded IGU with warm edge technology. This study demonstrates that remanufactured IGUs can achieve the performance of IGUs made from new glass.
Förderung
- Hochschule für angewandte Wissenschaften München
Zitieren
APA
Teich, M., Scherer, C., Schuster, M., Brandenstein, M., & Elstner, M. (2024). Reuse and remanufacturing of insulated glass units. Glass Structures & Engineering, 9(3-4), 339-356. https://doi.org/10.1007/s40940-024-00276-x
Vancouver
Teich M, Scherer C, Schuster M, Brandenstein M, Elstner M. Reuse and remanufacturing of insulated glass units. Glass Structures & Engineering. 2024;9(3-4):339-356. doi:10.1007/s40940-024-00276-x
BibTeX
@article{Teich2024,
author = {Teich, Martien and Scherer, Christian and Schuster, Miriam and Brandenstein, Max and Elstner, Michael},
title = {Reuse and remanufacturing of insulated glass units},
journal = {Glass Structures & Engineering},
year = {2024},
volume = {9},
number = {3-4},
pages = {339--356},
doi = {10.1007/s40940-024-00276-x}
}