EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Diagnostic accuracy of contrast-enhanced ultrasound versus duplex ultrasound and computed tomography angiography for endoleak detection after EVAR: a prospective comparative study

Wellington Gianoti Lustre, Libnah Leal, Vinicius Cardoso, Mateus Aves Borges Cristino, Carolina Dutra Queiroz Flumignan, Ronald Luiz Gomes Flumignan, Jorge Eduardo de Amorim, Luis Carlos Uta Nakano

Journal of Ultrasound · 2026

DOI: 10.1007/s40477-026-01182-4 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Ultrasound, 2026. Verfasst von Wellington Gianoti Lustre und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, 754, Rua Borges Lagoa, Vila Clementino, São Paulo, SP, 04038-001, B…. Hauptthemen laut MEDLINE: Endovascular Aneurysm Repair, Contrast Media, Endoleak, Computed Tomography Angiography. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Universidade Federal De São Paulo.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Lifelong imaging surveillance after endovascular aneurysm repair (EVAR) is essential for endoleak detection but is limited by cumulative radiation and nephrotoxicity from computed tomography angiography (CTA). Contrast-enhanced ultrasound (CEUS) has emerged as a promising alternative, although prospective comparative data remain limited.

Methods

In this prospective, single-centre diagnostic accuracy study, 30 consecutive patients (mean age 78.5 ± 7.1 years; 70% male) undergoing EVAR follow-up were evaluated with duplex ultrasound (DUS), CEUS (SonoVue®), and CTA within a 30-day interval. CTA served as the reference standard. Diagnostic performance metrics were calculated with 95% confidence intervals (CIs) according to STARD recommendations.

Results

Endoleaks were identified in 11 patients (36.7%). CTA detected 8 cases (26.7%), CEUS 9 (30.0%), and DUS 4 (13.3%). CEUS demonstrated high sensitivity (87.5%; 95% CI 47.3–99.7%) and specificity (90.9%; 70.8–98.9%), with overall accuracy of 90.0% (73.5–97.9%). In contrast, DUS showed limited sensitivity (33.3%; 9.9–65.1%) despite perfect specificity (100%), yielding lower accuracy (73.3%). Inter-modality agreement was 83.3%.

Conclusions

CEUS demonstrates high diagnostic accuracy for endoleak detection after EVAR and represents a robust, radiation-free alternative to CTA for longitudinal surveillance. Given its favourable safety profile and diagnostic performance, CEUS should be considered a first-line imaging modality in routine follow-up, with CTA reserved for equivocal findings or pre-interventional planning. These results support a paradigm shift toward CEUS-based surveillance strategies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endovascular Aneurysm RepairContrast MediaEndoleakComputed Tomography AngiographyUltrasonography, Doppler, DuplexHumansProspective StudiesMaleAgedSensitivity and SpecificityFemaleAged, 80 and overAortic Aneurysm, AbdominalUltrasonographyPhospholipidsSulfur Hexafluoride

Stichwörter der Autor:innen

Abdominal aortic aneurysmComputed tomography angiographyContrast-enhanced ultrasoundDiagnostic accuracyDuplex ultrasoundEndovascular aortic repair

Substanzen

Contrast Mediacontrast agent BR1PhospholipidsSulfur Hexafluoride

Autor:innen und Institutionen

  • Division of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, 754, Rua Borges Lagoa, Vila Clementino, São Paulo, SP, 04038-001, Brazil.
  • Division of Vascular Surgery, Hospital Mater Dei, Belo Horizonte, Brazil.
  • Division of Vascular Surgery, Centro Universitario Sao Camilo, São Paulo, Brazil.
  • Division of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, 754, Rua Borges Lagoa, Vila Clementino, São Paulo, SP, 04038-001, Brazil. flumignan@unifesp.br.

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
  • Universidade Federal De São Paulo

Zitieren

APA

Lustre, W. G., Leal, L., Cardoso, V., Cristino, M. A. B., Flumignan, C. D. Q., Flumignan, R. L. G., de Amorim, J. E., & Nakano, L. C. U. (2026). Diagnostic accuracy of contrast-enhanced ultrasound versus duplex ultrasound and computed tomography angiography for endoleak detection after EVAR: a prospective comparative study. Journal of Ultrasound. https://doi.org/10.1007/s40477-026-01182-4

Vancouver

Lustre WG, Leal L, Cardoso V, Cristino MAB, Flumignan CDQ, Flumignan RLG, et al. Diagnostic accuracy of contrast-enhanced ultrasound versus duplex ultrasound and computed tomography angiography for endoleak detection after EVAR: a prospective comparative study. Journal of Ultrasound. 2026. doi:10.1007/s40477-026-01182-4

BibTeX
@article{Lustre2026,
  author = {Lustre, Wellington Gianoti and Leal, Libnah and Cardoso, Vinicius and Cristino, Mateus Aves Borges and Flumignan, Carolina Dutra Queiroz and Flumignan, Ronald Luiz Gomes and de Amorim, Jorge Eduardo and Nakano, Luis Carlos Uta},
  title = {Diagnostic accuracy of contrast-enhanced ultrasound versus duplex ultrasound and computed tomography angiography for endoleak detection after EVAR: a prospective comparative study},
  journal = {Journal of Ultrasound},
  year = {2026},
  doi = {10.1007/s40477-026-01182-4}
}
Kostenlos starten →