EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Benchmark Sample Design for the Validation of Residual Stress Measurements by Diffraction: Insights and Practicalities

Gowtham Nimmal Haribabu, David Canelo-Yubero, Emad Maawad, Guilherme Abreu Faria, Peter Staron, Norbert Schell, Ranggi Sahmura Ramadhan, Sandra Cabeza, Arnold Paecklar, Thilo Pirling, Philip J. Withers, Matthew J. Roy

Integrating Materials and Manufacturing Innovation · 2024-12 · 13 (4) · 955-968

DOI: 10.1007/s40192-024-00385-z ↗

Kurz gefasst

Fachartikel in der Zeitschrift Integrating Materials and Manufacturing Innovation, online erschienen am 22.11.2024. Verfasst von Gowtham Nimmal Haribabu und 11 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union Horizon 2020 Easi-stress.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Non-destructive determination of residual stresses can present significant challenges. Two benchmark samples having the same geometry have been developed which can be measured by diffraction techniques and adapted to other material systems to validate RS measurements. While having the same geometry, one was solely elastically loaded while the other had stresses generated by significant plasticity. Measurements by a neutron diffraction and two synchrotron X-ray diffraction instruments (white beam and monochromatic beam) have been made in the ferrite phase at identical locations on S355 ferrite/pearlite steel benchmark samples. Broadly consistent results (± 30–50 MPa) are obtained across the three diffractometers. These results were corroborated by finite element predictions, with standard deviation on differences between predictions and measurements being ± 22 MPa for benchmarks with elastic sources of stress and ± 77 MPa for the plastically deformed case. Differences in the stresses were found when making near-surface measurements but only when around 80% of the gauge volume was outside the sample. The larger discrepancies between the measurements and the FE model in the plastic case may be due to plastic load transfer from the softer ferrite to the harder cementite during plastic deformation.

Förderung

  • European Union Horizon 2020 Easi-stress

Zitieren

APA

Haribabu, G. N., Canelo-Yubero, D., Maawad, E., Faria, G. A., Staron, P., Schell, N., Ramadhan, R. S., Cabeza, S., Paecklar, A., Pirling, T., Withers, P. J., & Roy, M. J. (2024). Benchmark Sample Design for the Validation of Residual Stress Measurements by Diffraction: Insights and Practicalities. Integrating Materials and Manufacturing Innovation, 13(4), 955-968. https://doi.org/10.1007/s40192-024-00385-z

Vancouver

Haribabu GN, Canelo-Yubero D, Maawad E, Faria GA, Staron P, Schell N, et al. Benchmark Sample Design for the Validation of Residual Stress Measurements by Diffraction: Insights and Practicalities. Integrating Materials and Manufacturing Innovation. 2024;13(4):955-968. doi:10.1007/s40192-024-00385-z

BibTeX
@article{Haribabu2024,
  author = {Haribabu, Gowtham Nimmal and Canelo-Yubero, David and Maawad, Emad and Faria, Guilherme Abreu and Staron, Peter and Schell, Norbert and Ramadhan, Ranggi Sahmura and Cabeza, Sandra and Paecklar, Arnold and Pirling, Thilo and Withers, Philip J. and Roy, Matthew J.},
  title = {Benchmark Sample Design for the Validation of Residual Stress Measurements by Diffraction: Insights and Practicalities},
  journal = {Integrating Materials and Manufacturing Innovation},
  year = {2024},
  volume = {13},
  number = {4},
  pages = {955--968},
  doi = {10.1007/s40192-024-00385-z}
}
Kostenlos starten →