EUVIMEDEUVIMED entdecken
Crossref

Dosimetric impact of knowledge-based automated planning using HyperArc for angiosarcoma of the scalp

Shoki Inui, Natsuo Tomita, Taiki Takaoka, Yoshihiro Ueda, Shingo Ohira, Yuya Nitta, Sayaka Kihara, Takahiro Tsuchiya, Yutaka Takahashi, Teiji Nishio, Masahiko Koizumi, Koji Konishi

Physical and Engineering Sciences in Medicine · 2026

DOI: 10.1007/s13246-026-01780-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, 2026. Verfasst von Shoki Inui und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuou-ku, Osaka, 541-8567, Japan. inui-sy@oici.jp. Hauptthemen laut MEDLINE: Scalp, Hemangiosarcoma, Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to automate and standardize treatment planning by comparing the dosimetric performance of conventional volumetric modulated arc therapy (C-VMAT) with that of HyperArc optimized using the knowledge-based RapidPlan model trained with the HyperArc plan (RP-HA) for total scalp irradiation (TSI) in the treatment of angiosarcoma of the scalp (AS). Additionally, this study compared the dosimetric performance of RP-HA with that of non-coplanar VMAT optimized using the same model (RP-NC-VMAT). From 40 patients with AS who had undergone TSI, 20 patients were selected for HyperArc planning and RapidPlan model training. The remaining 20 patients had treatment plans generated using three different methods (C-VMAT, RP-NC-VMAT, and RP-HA). The prescription doses were 70 and 56 Gy in 35 fractions of the target volumes, including gross tumor and whole scalp, respectively, using the simultaneous integrated boost technique. The dose distribution, dosimetric parameters, and dosimetric accuracy of each treatment plan were evaluated and compared between methods. None of the three methods exceeded the acceptable limits for all constraint parameters of the target and organs at risk. The RP-HA plan provided a significantly lower mean brain dose (10.96 ± 1.54 Gy) than the C-VMAT and RP-NC-VMAT plans (18.06 ± 2.17 Gy and 12.36 ± 2.12 Gy). The dose received by 0.1 cm^3 of the hippocampus was significantly lower in the RP-NC-VMAT and RP-HA plans than in the C-VMAT plan. The RapidPlan model trained with the HyperArc plan can be helpful in automating and standardizing treatment planning in TSI for AS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ScalpHemangiosarcomaRadiotherapy Planning, Computer-AssistedRadiotherapy, Intensity-ModulatedRadiometryKnowledge BasesHumansFemaleRadiotherapy DosageMaleAutomationMiddle AgedAdultAged

Stichwörter der Autor:innen

Angiosarcoma of the scalpHyperArcKnowledge-based planningRapidPlanRare tumorTotal scalp irradiation

Autor:innen und Institutionen

  • Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuou-ku, Osaka, 541-8567, Japan. inui-sy@oici.jp.
  • Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan.
  • Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuou-ku, Osaka, 541-8567, Japan.
  • Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan.
  • Medical Physics Laboratory, Division of Health Science, Graduate School of Medicine, The University of Osaka, Suita, Osaka, Japan.
  • Laboratory of Therapeutic Radiation Biology, Division of Health Science, Graduate School of Medicine, The University of Osaka, Suita, Osaka, Japan.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Inui, S., Tomita, N., Takaoka, T., Ueda, Y., Ohira, S., Nitta, Y., Kihara, S., Tsuchiya, T., Takahashi, Y., Nishio, T., Koizumi, M., & Konishi, K. (2026). Dosimetric impact of knowledge-based automated planning using HyperArc for angiosarcoma of the scalp. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-026-01780-w

Vancouver

Inui S, Tomita N, Takaoka T, Ueda Y, Ohira S, Nitta Y, et al. Dosimetric impact of knowledge-based automated planning using HyperArc for angiosarcoma of the scalp. Physical and Engineering Sciences in Medicine. 2026. doi:10.1007/s13246-026-01780-w

BibTeX
@article{Inui2026,
  author = {Inui, Shoki and Tomita, Natsuo and Takaoka, Taiki and Ueda, Yoshihiro and Ohira, Shingo and Nitta, Yuya and Kihara, Sayaka and Tsuchiya, Takahiro and Takahashi, Yutaka and Nishio, Teiji and Koizumi, Masahiko and Konishi, Koji},
  title = {Dosimetric impact of knowledge-based automated planning using HyperArc for angiosarcoma of the scalp},
  journal = {Physical and Engineering Sciences in Medicine},
  year = {2026},
  doi = {10.1007/s13246-026-01780-w}
}
Kostenlos starten →