Comparing fetal phantoms with surrogate organs in female phantoms during CT exposure of pregnant patients
Physical and Engineering Sciences in Medicine · 2024
DOI: 10.1007/s13246-024-01383-3 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Physical and Engineering Sciences in Medicine, 2024. Verfasst von Mohamed Khaldoun Badawy und 3 weiteren Autor:innen. Beteiligte Einrichtung: Monash Health Imaging, Monash Health, 246 Clayton Road, Clayton, VIC, 3168, Australia. mohamed.badawy@monashhealth.org. Hauptthemen laut MEDLINE: Fetus, Phantoms, Imaging, Tomography, X-Ray Computed, Radiation Dosage. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Monash University.
Abstract (Originalsprache)
With the rising use of Computed Tomography (CT) in diagnostic radiology, there are concerns regarding radiation exposure to sensitive groups, including pregnant patients. Accurately determining the radiation dose to the fetus during CT scans is essential to balance diagnostic efficacy with patient safety. This study assessed the accuracy of using the female uterus as a surrogate for fetal radiation dose during CT imaging. The study used common CT protocols to encompass various scenarios, including primary beam, scatter, and partial exposure. The computational program NCICT was used to calculate radiation doses for an adult female and a fetus phantom. The study highlighted that using the uterus for dose estimation can result in consistent underestimations of the effective dose, particularly when the fetus lies within the primary radiation beam. These discrepancies may influence clinical decisions, affecting care strategies and perceptions of associated risks. In conclusion, while the female uterus can indicate fetal radiation dose if the fetus is outside the primary beam, it is unreliable when the fetus is within the primary beam. More reliable abdomen/pelvic organs were recommended.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Monash Health Imaging, Monash Health, 246 Clayton Road, Clayton, VIC, 3168, Australia. mohamed.badawy@monashhealth.org.
- Department of Medical Imaging and Radiation Sciences, School of Primary and Allied Health Care, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, VIC, 3800, Australia. mohamed.badawy@monashhe…
- School of Life and Environmental Sciences, Deakin University, Burwood, VIC, 3125, Australia.
- Monash Health Imaging, Monash Health, 246 Clayton Road, Clayton, VIC, 3168, Australia.
Förderung
- Monash University
Zitieren
APA
Badawy, M. K., Kashish, K., Payne, S., & Masterson, M. (2024). Comparing fetal phantoms with surrogate organs in female phantoms during CT exposure of pregnant patients. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-024-01383-3
Vancouver
Badawy MK, Kashish K, Payne S, Masterson M. Comparing fetal phantoms with surrogate organs in female phantoms during CT exposure of pregnant patients. Physical and Engineering Sciences in Medicine. 2024. doi:10.1007/s13246-024-01383-3
BibTeX
@article{Badawy2024,
author = {Badawy, Mohamed Khaldoun and Kashish, Kashish and Payne, Shay and Masterson, Maeve},
title = {Comparing fetal phantoms with surrogate organs in female phantoms during CT exposure of pregnant patients},
journal = {Physical and Engineering Sciences in Medicine},
year = {2024},
doi = {10.1007/s13246-024-01383-3}
}
EUVIMED