EUVIMEDEUVIMED entdecken
Crossref

Treatment plan complexity metrics for predicting IMRT pre-treatment quality assurance results

S B Crowe, T Kairn, J Kenny, R T Knight, B Hill, C M Langton, J V Trapp

Australasian Physical & Engineering Sciences in Medicine · 2014-09 · 37 (3) · 475-482

DOI: 10.1007/s13246-014-0274-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Australasian Physical & Engineering Sciences in Medicine, online erschienen am 09.05.2014. Verfasst von S B Crowe und 6 weiteren Autor:innen. Beteiligte Einrichtung: Science and Engineering Faculty, Queensland University of Technology, Brisbane, QLD, Australia, sb.crowe@gmail.com. Die Arbeit wurde bisher 89-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The planning of IMRT treatments requires a compromise between dose conformity (complexity) and deliverability. This study investigates established and novel treatment complexity metrics for 122 IMRT beams from prostate treatment plans. The Treatment and Dose Assessor software was used to extract the necessary data from exported treatment plan files and calculate the metrics. For most of the metrics, there was strong overlap between the calculated values for plans that passed and failed their quality assurance (QA) tests. However, statistically significant variation between plans that passed and failed QA measurements was found for the established modulation index and for a novel metric describing the proportion of small apertures in each beam. The 'small aperture score' provided threshold values which successfully distinguished deliverable treatment plans from plans that did not pass QA, with a low false negative rate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HumansQuality Assurance, Health CareRadiotherapy Planning, Computer-AssistedRadiotherapy, Intensity-Modulated

Autor:innen und Institutionen

  • Science and Engineering Faculty, Queensland University of Technology, Brisbane, QLD, Australia, sb.crowe@gmail.com.

Zitieren

APA

Crowe, S. B., Kairn, T., Kenny, J., Knight, R. T., Hill, B., Langton, C. M., & Trapp, J. V. (2014). Treatment plan complexity metrics for predicting IMRT pre-treatment quality assurance results. Australasian Physical & Engineering Sciences in Medicine, 37(3), 475-482. https://doi.org/10.1007/s13246-014-0274-9

Vancouver

Crowe SB, Kairn T, Kenny J, Knight RT, Hill B, Langton CM, et al. Treatment plan complexity metrics for predicting IMRT pre-treatment quality assurance results. Australasian Physical & Engineering Sciences in Medicine. 2014;37(3):475-482. doi:10.1007/s13246-014-0274-9

BibTeX
@article{Crowe2014,
  author = {Crowe, S B and Kairn, T and Kenny, J and Knight, R T and Hill, B and Langton, C M and Trapp, J V},
  title = {Treatment plan complexity metrics for predicting IMRT pre-treatment quality assurance results},
  journal = {Australasian Physical & Engineering Sciences in Medicine},
  year = {2014},
  volume = {37},
  number = {3},
  pages = {475--482},
  doi = {10.1007/s13246-014-0274-9}
}
Kostenlos starten →