Comparative Technological Analysis of Durability and Reliability in Axial-Flow Pump Left Ventricular Assist Devices (LVADs)
Cardiovascular Engineering and Technology · 2025
DOI: 10.1007/s13239-025-00778-x ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Cardiovascular Engineering and Technology, 2025. Verfasst von Amin Khorshid Savar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai Interventional Medical Device Engineering Technology Research Center, University of Shanghai for Science and Technology, Shanghai, China. Hauptthemen laut MEDLINE: Heart-Assist Devices, Ventricular Function, Left, Heart Failure, Prosthesis Failure. Die Arbeit nennt 75 Literaturangaben. Gefördert von: Shanghai Engineering Research Center of Interventional Medical Device.
Abstract (Originalsprache)
PURPOSE: This study addresses the critical gap in the literature regarding the comparative analysis of axial flow left ventricular assist devices (LVADs). Despite technological advancements, there is a notable lack of integrated studies focusing solely on axial flow pumps and comparing multiple models with the same technology. This gap limits developers' access to comprehensive technical information essential for innovation in mechanical design, flow efficiency, and thrombus prevention. METHOD: A systematic review of 27 low-risk studies was performed on four axial flow LVADs: HeartMate II, DeBakey, Berlin Heart INCOR, and Jarvik 2000. The analysis evaluated durability and reliability using key metrics, including actuarial survival rates, device exchange rates, pump thrombosis rates, and freedom from adverse events, while considering technical factors such as rotor design, flow dynamics, and material innovation. RESULTS: HeartMate II achieved a 79% actuarial survival rate at 1 year and a 6.3% thrombosis-related exchange rate. DeBakey had a higher exchange rate of 33.3% due to mechanical issues, indicating a need for better material durability. Jarvik 2000 offered long-term support with a 5-year duration and an 8.3% thrombosis rate, benefiting from its spiral cable design. INCOR showed high reliability with low energy consumption and minimal driveline infections, highlighting the advantages of advanced coatings and reduced friction. CONCLUSION: Axial flow LVADs are crucial for patients with small chest spaces, especially children. Enhancements in rotor design, materials, and real-time monitoring are essential for improving durability and reliability. These findings provide valuable insights for developing more durable and reliable axial flow pumps.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Shanghai Interventional Medical Device Engineering Technology Research Center, University of Shanghai for Science and Technology, Shanghai, China.
- Shanghai Interventional Medical Device Engineering Technology Research Center, University of Shanghai for Science and Technology, Shanghai, China. cyz2008@usst.edu.cn.
ORCID-Profile: Amin Khorshid Savar
Förderung
- Shanghai Engineering Research Center of Interventional Medical Device
Zitieren
APA
Khorshid Savar, A., Wang, H., Chen, N., & Cheng, Y. (2025). Comparative Technological Analysis of Durability and Reliability in Axial-Flow Pump Left Ventricular Assist Devices (LVADs). Cardiovascular Engineering and Technology. https://doi.org/10.1007/s13239-025-00778-x
Vancouver
Khorshid Savar A, Wang H, Chen N, Cheng Y. Comparative Technological Analysis of Durability and Reliability in Axial-Flow Pump Left Ventricular Assist Devices (LVADs). Cardiovascular Engineering and Technology. 2025. doi:10.1007/s13239-025-00778-x
BibTeX
@article{KhorshidSavar2025,
author = {Khorshid Savar, Amin and Wang, Hongrui and Chen, Nuo and Cheng, Yunzhang},
title = {Comparative Technological Analysis of Durability and Reliability in Axial-Flow Pump Left Ventricular Assist Devices (LVADs)},
journal = {Cardiovascular Engineering and Technology},
year = {2025},
doi = {10.1007/s13239-025-00778-x}
}
EUVIMED