EUVIMEDEUVIMED entdecken
Crossref

Arteriolar Elasticity Measurement in the Fingertip Based on Photoplethysmographic Volume-Oscillometry: A New Approach to the Assessment of Vasomotor Functions in the Microvasculature

Ken-Ichi Yamakoshi iD, Peter Rolfe iD, Takehiro Yamakoshi iD

Cardiovascular Engineering and Technology · 2025

DOI: 10.1007/s13239-025-00772-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiovascular Engineering and Technology, 2025. Verfasst von Ken-Ichi Yamakoshi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Showa University School of Medicine, Shinagawa, Tokyo, 142-8555, Japan. Hauptthemen laut MEDLINE: Fingers, Photoplethysmography, Oscillometry, Microcirculation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Dysfunction of vasomotor reactions due to arteriolar smooth muscle causes serious adverse events, such as loss of hemodynamic coherence. This in turn can increase risks of cardiovascular-related diseases. A noninvasive and quantitative evaluation of microvascular disorder is therefore very important for early diagnosis and treatment. This paper describes a new approach to the assessment of vasomotor functions using the arteriolar elasticity measurement technique in the fingertip. METHODS: A recently developed device, modified to detect a photoplethysmogram with green light (gPPG) in arteriolar regions, allowed the measurement of arteriolar blood pressure (BPca.) and gPPG from a left index fingertip placed on an occlusive cuff of the device. Arteriolar stiffness and distensibility were analyzed as effective elasticity indices, as a function of arteriolar distending pressure derived by volume-oscillometry. Cold pressor tests to induce vasoconstriction were carried out whether appropriate elasticity changes could be obtained. RESULTS: Experiments using 6 healthy subjects were successfully made to obtain arteriolar elastic properties before and while immersing a right hand in cold water. The index-values of stiffness and distensibility showed, respectively, a considerable increase and decrease, clearly demonstrating the appropriate elasticity changes with vasoconstrictive reactions. CONCLUSION: Although a further study using many subjects is needed, the results so far suggest that this method could easily provide important features to acquire quantitatively arteriolar elasticity together with BPca. and to assess vasomotor functions in the microvasculature. This convenient method appears useful for clinical practices and health management and promising also for screening cardiovascular-related diseases. (242/250 words).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FingersPhotoplethysmographyOscillometryMicrocirculationVascular StiffnessVasomotor SystemHumansArteriolesMaleAdultVasoconstrictionFemaleElasticityBlood PressurePredictive Value of TestsEquipment DesignYoung Adult

Stichwörter der Autor:innen

Arteriolar elasticityGreen light photoplethymographyMicrovasculatureNoninvasive evaluationVasomotor functionVolume-oscillometry

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Showa University School of Medicine, Shinagawa, Tokyo, 142-8555, Japan.
  • College of Science and Engineering, Kanazawa University, Kanazawa, Ishikawa, 920-1192, Japan.
  • Department of Research and Development, Nonprofit Organization of Research Institute of Life Benefit, Sapporo, Hokkaido, 005-0006, Japan.
  • Department of Automatic Measurement and Control, Harbin Institute of Technology, No. 92 West Dazhi Street, Nan Gang District, Harbin, Heilongjiang Province, 150001, China.
  • Science and Technology, Oxford BioHorizons, 12 Park View Road, Berkhamsted, UK.
  • Department of Research and Development, Nonprofit Organization of Research Institute of Life Benefit, Sapporo, Hokkaido, 005-0006, Japan. takehiroy@me.com.

ORCID-Profile: Ken-Ichi Yamakoshi, Peter Rolfe, Takehiro Yamakoshi

Zitieren

APA

Yamakoshi, K. I., Rolfe, P., & Yamakoshi, T. (2025). Arteriolar Elasticity Measurement in the Fingertip Based on Photoplethysmographic Volume-Oscillometry: A New Approach to the Assessment of Vasomotor Functions in the Microvasculature. Cardiovascular Engineering and Technology. https://doi.org/10.1007/s13239-025-00772-3

Vancouver

Yamakoshi KI, Rolfe P, Yamakoshi T. Arteriolar Elasticity Measurement in the Fingertip Based on Photoplethysmographic Volume-Oscillometry: A New Approach to the Assessment of Vasomotor Functions in the Microvasculature. Cardiovascular Engineering and Technology. 2025. doi:10.1007/s13239-025-00772-3

BibTeX
@article{Yamakoshi2025,
  author = {Yamakoshi, Ken-Ichi and Rolfe, Peter and Yamakoshi, Takehiro},
  title = {Arteriolar Elasticity Measurement in the Fingertip Based on Photoplethysmographic Volume-Oscillometry: A New Approach to the Assessment of Vasomotor Functions in the Microvasculature},
  journal = {Cardiovascular Engineering and Technology},
  year = {2025},
  doi = {10.1007/s13239-025-00772-3}
}
Kostenlos starten →