EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseVergleichsstudieOpen Access · CC BY 4.0

Aortic valve area determination by planimetry: comparison of two-dimensional and three-dimensional transesophageal echocardiography – a systematic review and meta-analysis

Paula Fazendas, Daniel Caldeira, Helder Pereira, Ana G Almeida

Journal of Echocardiography · 30.05.2026

DOI: 10.1007/s12574-026-00734-1 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Echocardiography, online erschienen am 30.05.2026. Verfasst von Paula Fazendas und 3 weiteren Autor:innen. Beteiligte Einrichtung: Centro Academico de Medicina de Lisboa, CCUL@RISE, Faculty of Medicine, Servico de Cardiologia, University of Lisbon, Hospital Garcia de Orta, Unidad…. Hauptthemen laut MEDLINE: Echocardiography, Transesophageal, Echocardiography, Three-Dimensional, Aortic Valve, Aortic Valve Stenosis. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidade de Lisboa.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Accurate quantification of aortic valve area (AVA) is essential in the evaluation of aortic stenosis (AS) severity. While two-dimensional (2D) Transesophageal echocardiography (TEE) is widely used for AVA planimetry, three-dimensional (3D) TEE may offer superior accuracy due to improved anatomical visualization. We aimed to compare AVA measurements by 2D versus 3D TEE in patients with AS.

Methods

We conducted a systematic review and meta-analysis of studies reporting AVA measurements using both 2D and 3D TEE in adult patients with AS. Paired measurements, means and standard deviations, or correlations between techniques were extracted. The primary outcome was the mean difference in AVA (cm²) between modalities. Secondary outcomes included pooled correlation coefficients and assessment of heterogeneity. Analyses were performed using random-effects models. Eight studies comprising 381 patients were included. The pooled mean absolute difference between 2D and 3D TEE was 0.16 cm² (95% CI 0.09–0.23; p < 0.001), indicating that 3D TEE yielded slightly smaller AVA measurements overall, with a tendency to lower interobserver variability. Heterogeneity was low, and sensitivity analyses excluding older equipment showed consistent findings. Most studies demonstrated low risk of bias in patient selection and flow/timing, with some concerns regarding index-test and reference-standard domains.

Conclusions

3D TEE provides slightly smaller AVA measurements than 2D TEE, with low heterogeneity and acceptable study quality. While both modalities may be clinically useful, 3D TEE may offer more reliable anatomical assessment. Standardized imaging protocols and multicenter validation are warranted to enhance reproducibility and ensure consistent evaluation of AS severity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echocardiography, TransesophagealEchocardiography, Three-DimensionalAortic ValveAortic Valve StenosisHumansReproducibility of Results

Stichwörter der Autor:innen

Aortic stenosisMeta-analysisPlanimetrySystematic reviewThree-dimensional transesophageal echocardiographyTwo-dimensional transesophageal echocardiography

Autor:innen und Institutionen

  • Centro Academico de Medicina de Lisboa, CCUL@RISE, Faculty of Medicine, Servico de Cardiologia, University of Lisbon, Hospital Garcia de Orta, Unidade Local de Saude Almada Seixal, Lisboa, Portugal. pfazendas@hotmail.co…
  • Cardiology Department, Hospital Garcia de Orta, Av. Professor Torrado da Silva, Almada, 2805-267, Portugal. pfazendas@hotmail.com.
  • Centro Academico de Medicina de Lisboa, CCUL@RISE, Faculty of Medicine, Servico de Cardiologia, University of Lisbon, Hospital Garcia de Orta, Unidade Local de Saude Almada Seixal, Lisboa, Portugal.
  • Servico de Cardiologia, Departamento de Coracao e Vasos, Centro Academico de Medicina de Lisboa CCUL@RISE, Faculty of Medicine, Centro Hospital Universitario Lisboa Norte (CHULN), Unidade Local de Saude Santa Maria, Uni…
  • Cardiology Department, Hospital Garcia de Orta, Av. Professor Torrado da Silva, Almada, 2805-267, Portugal.

Förderung

  • Universidade de Lisboa

Zitieren

APA

Fazendas, P., Caldeira, D., Pereira, H., & Almeida, A. G. (2026). Aortic valve area determination by planimetry: comparison of two-dimensional and three-dimensional transesophageal echocardiography – a systematic review and meta-analysis. Journal of Echocardiography. https://doi.org/10.1007/s12574-026-00734-1

Vancouver

Fazendas P, Caldeira D, Pereira H, Almeida AG. Aortic valve area determination by planimetry: comparison of two-dimensional and three-dimensional transesophageal echocardiography – a systematic review and meta-analysis. Journal of Echocardiography. 2026. doi:10.1007/s12574-026-00734-1

BibTeX
@article{Fazendas2026,
  author = {Fazendas, Paula and Caldeira, Daniel and Pereira, Helder and Almeida, Ana G},
  title = {Aortic valve area determination by planimetry: comparison of two-dimensional and three-dimensional transesophageal echocardiography – a systematic review and meta-analysis},
  journal = {Journal of Echocardiography},
  year = {2026},
  doi = {10.1007/s12574-026-00734-1}
}
Kostenlos starten →