Spatiotemporal Gait Analysis of Patients with Spinocerebellar Ataxia Types 3 and 10 Using Inertial Measurement Units: A Comparative Study
The Cerebellum · 2024
DOI: 10.1007/s12311-024-01709-7 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Cerebellum, 2024. Verfasst von Igor Barcellos und 7 weiteren Autor:innen. Beteiligte Einrichtung: Movement Disorders Unit, Neurology Service, Internal Medicine Department, Hospital de Clínicas, Federal University of Paraná, Curitiba, Brazil. igorc…. Hauptthemen laut MEDLINE: Gait Analysis, Spinocerebellar Ataxias, Machado-Joseph Disease. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 75 Literaturangaben.
Abstract (Originalsprache)
Given the high morbidity related to the progression of gait deficits in spinocerebellar ataxias (SCA), there is a growing interest in identifying biomarkers that can guide early diagnosis and rehabilitation. Spatiotemporal parameter (STP) gait analysis using inertial measurement units (IMUs) has been increasingly studied in this context. This study evaluated STP profiles in SCA types 3 and 10, compared them to controls, and correlated them with clinical scales. IMU portable sensors were used to measure STPs under four gait conditions: self-selected pace (SSP), fast pace (FP), fast pace checking-boxes (FPCB), and fast pace with serial seven subtractions (FPS7). Compared to healthy subjects, both SCA groups had higher values for step time, variability, and swing time, with lower values for gait speed, cadence, and step length. We also found a reduction in speed gain capacity in both SCA groups compared to controls and an increase in speed dual-task cost in the SCA10 group. However, there were no significant differences between the SCA groups. Swing time, mean speed, and step length were correlated with disease severity, risk of falling and functionality in both clinical groups. In the SCA3 group, fear of falling was correlated with cadence. In the SCA10 group, results of the Montreal cognitive assessment test were correlated with step time, mean speed, and step length. These results show that individuals with SCA3 and SCA10 present a highly variable, short-stepped, slow gait pattern compared to healthy subjects, and their gait quality worsened with a fast pace and dual-task involvement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Movement Disorders Unit, Neurology Service, Internal Medicine Department, Hospital de Clínicas, Federal University of Paraná, Curitiba, Brazil. igorcellos@gmail.com.
- Department of Neurology, University Hospital Schleswig-Holstein and Kiel University, Kiel, Germany.
- Movement Disorders Unit, Neurology Service, Internal Medicine Department, Hospital de Clínicas, Federal University of Paraná, Curitiba, Brazil.
- Gloria and Morton Shulman Movement Disorders Centre, Toronto Western Hospital, University of Toronto, Toronto, Canada.
Zitieren
APA
Barcellos, I., Hansen, C., Strobel, G. K., Geritz, J., Munhoz, R. P., Moscovich, M., Maetzler, W., & Teive, H. A. G. (2024). Spatiotemporal Gait Analysis of Patients with Spinocerebellar Ataxia Types 3 and 10 Using Inertial Measurement Units: A Comparative Study. The Cerebellum. https://doi.org/10.1007/s12311-024-01709-7
Vancouver
Barcellos I, Hansen C, Strobel GK, Geritz J, Munhoz RP, Moscovich M, et al. Spatiotemporal Gait Analysis of Patients with Spinocerebellar Ataxia Types 3 and 10 Using Inertial Measurement Units: A Comparative Study. The Cerebellum. 2024. doi:10.1007/s12311-024-01709-7
BibTeX
@article{Barcellos2024,
author = {Barcellos, Igor and Hansen, Clint and Strobel, Giovanna Klüppel and Geritz, Johanna and Munhoz, Renato P and Moscovich, Mariana and Maetzler, Walter and Teive, Hélio Afonso Ghizoni},
title = {Spatiotemporal Gait Analysis of Patients with Spinocerebellar Ataxia Types 3 and 10 Using Inertial Measurement Units: A Comparative Study},
journal = {The Cerebellum},
year = {2024},
doi = {10.1007/s12311-024-01709-7}
}
EUVIMED