EUVIMEDEUVIMED entdecken
Crossref

Step Width Haptic Feedback for Gait Stability in Spinocerebellar Ataxia: Preliminary Results

Hong Wang iD, Zakir Ullah, Eran Gazit, Marina Brozgol, Jeffrey M Hausdorff, Peter B Shull, Penina Ponger

Movement Disorders · 2025

DOI: 10.1002/mds.30117 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Movement Disorders, 2025. Verfasst von Hong Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China. Hauptthemen laut MEDLINE: Spinocerebellar Ataxias, Gait, Gait Disorders, Neurologic, Biofeedback, Psychology. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Chief Scientist Office, Ministry of Health, Israel.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Wider step width and lower step‐to‐step variability are linked to improved gait stability and reduced fall risk. It is unclear if patients with spinocerebellar ataxia (SCA) can learn to adjust these aspects of gait to reduce fall risk.

Objectives

The aims were to examine the possibility of using wearable step width haptic biofeedback to enhance gait stability and reduce fall risk in individuals with SCA.

Methods

Thirteen people with SCA type 3 performed step width training (single session) using real‐time feedback.

Results

Step width increased post‐training (19.3 cm, interquartile range [IQR] 16.3–20.2 cm) and at retention (16.6 cm, IQR 16.2–21.1 cm), compared to baseline (11.0 cm, IQR 5.2–15.2 cm; P < 0.001). Step width variability decreased during post‐training (19.7%, IQR 17.4%–26.2%) and at retention (22.3%, IQR 18.6%–30.2%), compared to baseline (44.5%, IQR 28.5%–71.2%; P < 0.001). Crossover steps, another mark of instability, decreased after training ( P < 0.031).

Conclusions

These pilot results suggest that patients with SCA can use a novel, wearable biofeedback system to improve their gait stability. © 2025 International Parkinson and Movement Disorder Society.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spinocerebellar AtaxiasGaitGait Disorders, NeurologicBiofeedback, PsychologyPostural BalanceFeedback, SensoryMachado-Joseph DiseaseHumansMaleFemaleMiddle AgedAdultAgedAccidental Falls

Stichwörter der Autor:innen

gait stabilitygait traininghaptic biofeedbackspinocerebellar ataxiastep width

Autor:innen und Institutionen

  • School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • Center for the Study of Movement, Cognition and Mobility, Neurological Institute, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
  • Sagol School of Neuroscience and Department of Physical Therapy, Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel.
  • Department of Orthopedic Surgery and Rush Alzheimer's Disease Center, Rush University Medical Center, Chicago, Illinois, USA.
  • Department of Neurology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
  • Genetics Institute and Genomics Center, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.

ORCID-Profile: Hong Wang

Förderung

  • National Natural Science Foundation of China
  • Chief Scientist Office, Ministry of Health, Israel

Zitieren

APA

Wang, H., Ullah, Z., Gazit, E., Brozgol, M., Hausdorff, J. M., Shull, P. B., & Ponger, P. (2025). Step Width Haptic Feedback for Gait Stability in Spinocerebellar Ataxia: Preliminary Results. Movement Disorders. https://doi.org/10.1002/mds.30117

Vancouver

Wang H, Ullah Z, Gazit E, Brozgol M, Hausdorff JM, Shull PB, et al. Step Width Haptic Feedback for Gait Stability in Spinocerebellar Ataxia: Preliminary Results. Movement Disorders. 2025. doi:10.1002/mds.30117

BibTeX
@article{Wang2025,
  author = {Wang, Hong and Ullah, Zakir and Gazit, Eran and Brozgol, Marina and Hausdorff, Jeffrey M and Shull, Peter B and Ponger, Penina},
  title = {Step Width Haptic Feedback for Gait Stability in Spinocerebellar Ataxia: Preliminary Results},
  journal = {Movement Disorders},
  year = {2025},
  doi = {10.1002/mds.30117}
}
Kostenlos starten →