Mechanical failure of modular hip stems due to titanium alloy neck breakage: a single-center case series
MUSCULOSKELETAL SURGERY · 2025
DOI: 10.1007/s12306-025-00935-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift MUSCULOSKELETAL SURGERY, 2025. Verfasst von N Papapietro und 7 weiteren Autor:innen. Beteiligte Einrichtung: Operative Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, 00128, Roma, Italy. Hauptthemen laut MEDLINE: Prosthesis Failure, Hip Prosthesis, Titanium, Arthroplasty, Replacement, Hip. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
BACKROUND: Modular neck implants in total hip arthroplasty (THA) allow control of length, offset, and version. However, these implants showed problems such as implant fracture and adverse reactions due to metal debris. This study aims to analyze our modular titanium-titanium neck THA stems, focus on mechanical complications related to its breakage, conduct a metallurgical analysis on these broken implants, and report revision surgery outcomes. METHODS: We performed a retrospective review to identify patients who had undergone THA with a specific modular (H2M-C2F Implants) implant at our institute (Fondazione Policlinico Universitario Campus Bio-Medico, Rome). Patient demographics, implant characteristics, clinical follow-up, and revision outcomes were obtained. A metallurgical examination was conducted on the broken implants. RESULTS: Out of thirty-eight patients eligible patients, seventeen had a titanium alloy neck, whereas the remaining twenty-one had CrCo necks. Thirteen of seventeen patients with titanium necks reported spontaneous ruptures of the neck due to fretting corrosion phenomena. Revision surgery was offered to all patients, including the ones who did not experience spontaneous rupture (four patients). Neither intraoperative nor long-term complications were reported, except for one patient who showed gluteal insufficiency. No clinical differences were reported between the patients who underwent revision surgery and those who were revised preventively. CONCLUSION: Using modular implants should be limited to strict indications. Patients' characteristics are vital in selecting the ideal candidate for a modular THA. Modular implants should answer all the questions regarding durability and fracture risk to become a valid alternative to fixed-neck stems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Operative Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, 00128, Roma, Italy.
- Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, 00128, Roma, Italy.
- BIOMORF Department, Biomedical, Dental and Morphological and Functional Images, University of Messina, 98124, Messina, Italy.
- Operative Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, 00128, Roma, Italy. clemente.caria@unicampus.it.
- Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, 00128, Roma, Italy. clemente.caria@unicampus.it.
- Orthopedic and Traumatology Department, IRCCS Istituto Ortopedico Rizzoli, 40136, Bologna, Italy.
Zitieren
APA
Papapietro, N., Zampogna, B., Caria, C., Giusti, S., Marinozzi, A., Di Martino, A., Papalia, R., & Denaro, V. (2025). Mechanical failure of modular hip stems due to titanium alloy neck breakage: a single-center case series. MUSCULOSKELETAL SURGERY. https://doi.org/10.1007/s12306-025-00935-4
Vancouver
Papapietro N, Zampogna B, Caria C, Giusti S, Marinozzi A, Di Martino A, et al. Mechanical failure of modular hip stems due to titanium alloy neck breakage: a single-center case series. MUSCULOSKELETAL SURGERY. 2025. doi:10.1007/s12306-025-00935-4
BibTeX
@article{Papapietro2025,
author = {Papapietro, N and Zampogna, B and Caria, C and Giusti, S and Marinozzi, A and Di Martino, A and Papalia, R and Denaro, V},
title = {Mechanical failure of modular hip stems due to titanium alloy neck breakage: a single-center case series},
journal = {MUSCULOSKELETAL SURGERY},
year = {2025},
doi = {10.1007/s12306-025-00935-4}
}
EUVIMED