EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Numerical Analysis of Coaxially 3D Printed Lunar Habitats: Integrating Regolith and PCM for Passive Temperature Control

A. Borshchak Kachalov, P. Salgado Sánchez, M. T. Mollah, J. M. Ezquerro, J. Spangenberg, B. Šeta

Microgravity Science and Technology · 05.07.2025 · 37 (4)

DOI: 10.1007/s12217-025-10194-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microgravity Science and Technology, online erschienen am 05.07.2025. Verfasst von A. Borshchak Kachalov und 5 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 84 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerio de Ciencia e Innovación, Innovation Fund Denmark.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Space research is shifting its focus from low-gravity platforms to Moon and Mars exploration, requiring advanced habitat construction. This paper proposes to integrate the 3D printing of regolith and Phase Change Materials (PCM), with a particular interest in lunar habitats. A coaxial printing approach is numerically analyzed, enabling the simultaneous deposition of a regolith shell, providing structural integrity, and a PCM core that helps regulate the interior habitat temperature in a passive manner. Simulations show that 3D printing with a coaxial nozzle can effectively control the shell-core (internal) structure of the habitat wall by adjusting printing parameters or by constructing multi-strand composite walls. The PCM core becomes thicker when using a smaller layer height or a higher extrusion speed during printing. We then examine the expected thermal response of the habitat, initially made of pure regolith and later incorporating the PCM. With just regolith, results indicate that one can select adequate thermo-optical properties at the wall external boundary, and wall thickness, to control the mean temperature in the interior, and associated fluctuations, respectively. Incorporating the PCM, either in single or multiple regolith-PCM strands, is shown to effectively stabilize this internal temperature ( $$\Delta T_\textrm{i} \rightarrow 0$$ Δ T i → 0 K), improving thermal performance and habitat design, and reducing the quantity of required regolith and binder. Since binder has to be brought from Earth, this reduction can be a major factor in enabling sustainable construction on the Moon and beyond.

Förderung

  • Ministerio de Ciencia e Innovación
  • Innovation Fund Denmark

Zitieren

APA

Kachalov, A. B., Sánchez, P. S., Mollah, M. T., Ezquerro, J. M., Spangenberg, J., & Šeta, B. (2025). Numerical Analysis of Coaxially 3D Printed Lunar Habitats: Integrating Regolith and PCM for Passive Temperature Control. Microgravity Science and Technology, 37(4). https://doi.org/10.1007/s12217-025-10194-4

Vancouver

Kachalov AB, Sánchez PS, Mollah MT, Ezquerro JM, Spangenberg J, Šeta B. Numerical Analysis of Coaxially 3D Printed Lunar Habitats: Integrating Regolith and PCM for Passive Temperature Control. Microgravity Science and Technology. 2025;37(4). doi:10.1007/s12217-025-10194-4

BibTeX
@article{Kachalov2025,
  author = {Kachalov, A. Borshchak and Sánchez, P. Salgado and Mollah, M. T. and Ezquerro, J. M. and Spangenberg, J. and Šeta, B.},
  title = {Numerical Analysis of Coaxially 3D Printed Lunar Habitats: Integrating Regolith and PCM for Passive Temperature Control},
  journal = {Microgravity Science and Technology},
  year = {2025},
  volume = {37},
  number = {4},
  doi = {10.1007/s12217-025-10194-4}
}
Kostenlos starten →