Quantification of uncertainties in reference and relative dose measurements, dose calculations, and patient setup in modern external beam radiotherapy
Radiological Physics and Technology · 2025
DOI: 10.1007/s12194-024-00856-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiological Physics and Technology, 2025. Verfasst von Naoki Kinoshita und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Faculty of Medical Sciences, University of Fukui, 23-3, Matsuoka-Shimoaituki, Eiheiji, Yoshida, Fukui, 910-1193, Japan. nkin…. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiometry, Radiation Dosage. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Fukui, Japanese Society of Radiological Technology.
Abstract (Originalsprache)
Uncertainties in the steps of external beam radiotherapy (EBRT) affect patient outcomes. However, few studies have investigated major contributors to these uncertainties. This study investigated factors contributing to reducing uncertainty in delivering a dose to a target volume. The EBRT process was classified into four steps: reference dosimetry, relative dosimetry [percentage depth doses (PDDs) and off-center ratios (OCRs)], dose calculations (PDDs and OCRs in a virtual water phantom), and patient setup using an image-guided radiation therapy system. We evaluated the uncertainties for these steps in conventionally fractionated EBRT for intracranial disease using 4-, 6-, and 10-MV flattened photon beams generated from clinical linear accelerators following the Guide to the Expression of Uncertainty in Measurement and an uncertainty evaluation method with uncorrected deflection. The following were the major contributors to these uncertainties: beam quality conversion factors for reference dosimetry; charge measurements, chamber depth, source-to-surface distance, water evaporation, and field size for relative dosimetry; dose calculation accuracy for the dose calculations; image registration, radiation-imaging isocenter coincidence, variation in radiation isocenter due to gantry and couch rotation, and intrafractional motion for the patient setup. Among the four steps, the relative dosimetry and dose calculation (namely, both penumbral OCRs) steps involved an uncertainty of more than 5% with a coverage factor of 1. In the EBRT process evaluated herein, the uncertainties in the relative dosimetry and dose calculations must be reduced.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Faculty of Medical Sciences, University of Fukui, 23-3, Matsuoka-Shimoaituki, Eiheiji, Yoshida, Fukui, 910-1193, Japan. nkino@u-fukui.ac.jp.
- National Metrology Institute of Japan, AIST, Tsukuba, Japan.
- Section of Radiation Safety and Quality Assurance, National Cancer Center Hospital East, Kashiwa, Japan.
- Division of Clinical Radiology Service, Kyoto University Hospital, Kyoto, Japan.
- Seikeikai Medical College, Sakai, Japan.
- Radiological Technology Department, Iida Municipal Hospital, Iida, Japan.
Förderung
- University of Fukui
- Japanese Society of Radiological Technology
Zitieren
APA
Kinoshita, N., Shimizu, M., Motegi, K., Tsuruta, Y., Takakura, T., Oguchi, H., & Kurokawa, C. (2025). Quantification of uncertainties in reference and relative dose measurements, dose calculations, and patient setup in modern external beam radiotherapy. Radiological Physics and Technology. https://doi.org/10.1007/s12194-024-00856-0
Vancouver
Kinoshita N, Shimizu M, Motegi K, Tsuruta Y, Takakura T, Oguchi H, et al. Quantification of uncertainties in reference and relative dose measurements, dose calculations, and patient setup in modern external beam radiotherapy. Radiological Physics and Technology. 2025. doi:10.1007/s12194-024-00856-0
BibTeX
@article{Kinoshita2025,
author = {Kinoshita, Naoki and Shimizu, Morihito and Motegi, Kana and Tsuruta, Yusuke and Takakura, Toru and Oguchi, Hiroshi and Kurokawa, Chie},
title = {Quantification of uncertainties in reference and relative dose measurements, dose calculations, and patient setup in modern external beam radiotherapy},
journal = {Radiological Physics and Technology},
year = {2025},
doi = {10.1007/s12194-024-00856-0}
}
EUVIMED