Verification of image quality improvement by deep learning reconstruction to 1.5 T MRI in T2-weighted images of the prostate gland
Radiological Physics and Technology · 2024
DOI: 10.1007/s12194-024-00819-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiological Physics and Technology, 2024. Verfasst von Yoshiomi Sato und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Saitama City Hospital, Mimuro 2460, Saitama, 336-8522, Japan. yoshiomi@msh.biglobe.ne.jp. Hauptthemen laut MEDLINE: Deep Learning, Magnetic Resonance Imaging, Prostate, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
This study aimed to evaluate whether the image quality of 1.5 T magnetic resonance imaging (MRI) of the prostate is equal to or higher than that of 3 T MRI by applying deep learning reconstruction (DLR). To objectively analyze the images from the 13 healthy volunteers, we measured the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the images obtained by the 1.5 T scanner with and without DLR, as well as for images obtained by the 3 T scanner. In the subjective, T2W images of the prostate were visually evaluated by two board-certified radiologists. The SNRs and CNRs in 1.5 T images with DLR were higher than that in 3 T images. Subjective image scores were better for 1.5 T images with DLR than 3 T images. The use of the DLR technique in 1.5 T MRI substantially improved the SNR and image quality of T2W images of the prostate gland, as compared to 3 T MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Saitama City Hospital, Mimuro 2460, Saitama, 336-8522, Japan. yoshiomi@msh.biglobe.ne.jp.
- Department of Diagnostic Radiology, Saitama City Hospital, Mimuro 2460, Saitama, 336-8522, Japan.
Zitieren
APA
Sato, Y., & Ohkuma, K. (2024). Verification of image quality improvement by deep learning reconstruction to 1.5 T MRI in T2-weighted images of the prostate gland. Radiological Physics and Technology. https://doi.org/10.1007/s12194-024-00819-5
Vancouver
Sato Y, Ohkuma K. Verification of image quality improvement by deep learning reconstruction to 1.5 T MRI in T2-weighted images of the prostate gland. Radiological Physics and Technology. 2024. doi:10.1007/s12194-024-00819-5
BibTeX
@article{Sato2024,
author = {Sato, Yoshiomi and Ohkuma, Kiyoshi},
title = {Verification of image quality improvement by deep learning reconstruction to 1.5 T MRI in T2-weighted images of the prostate gland},
journal = {Radiological Physics and Technology},
year = {2024},
doi = {10.1007/s12194-024-00819-5}
}
EUVIMED