EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cone Beam Computed Tomography Image-Quality Improvement Using “One-Shot” Super-resolution

Takumasa Tsuji, Soichiro Yoshida, Mitsuki Hommyo, Asuka Oyama, Shinobu Kumagai, Kenshiro Shiraishi, Jun'ichi Kotoku

Journal of Imaging Informatics in Medicine · 2024

DOI: 10.1007/s10278-024-01346-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Imaging Informatics in Medicine, 2024. Verfasst von Takumasa Tsuji und 6 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Medical Care and Technology, Teikyo University, 2-11-1 Kaga, Itabashi-Ku, Tokyo, 173-8605, Japan. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Quality Improvement, Prostatic Neoplasms, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Japan Science and Technology Agency.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cone beam computed tomography (CBCT) images are convenient representations for obtaining information about patients’ internal organs, but their lower image quality than those of treatment planning CT images constitutes an important shortcoming. Several proposed CBCT image-quality improvement methods based on deep learning require large amounts of training data. Our newly developed model using a super-resolution method, “one-shot” super-resolution (OSSR) based on the “zero-shot” super-resolution method, requires only small amounts of training data to improve CBCT image quality using only the target CBCT image and the paired treatment planning CT image. For this study, pelvic CBCT images and treatment planning CT images of 30 prostate cancer patients were used. We calculated the root mean squared error (RMSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM) to evaluate image-quality improvement and normalized mutual information (NMI) as a quantitative evaluation of positional accuracy. Our proposed method can improve CBCT image quality without requiring large amounts of training data. After applying our proposed method, the resulting RMSE, PSNR, SSIM, and NMI between the CBCT images and the treatment planning CT images were as much as 0.86, 1.05, 1.03, and 1.31 times better than those obtained without using our proposed method. By comparison, CycleGAN exhibited values of 0.91, 1.03, 1.02, and 1.16. The proposed method achieved performance equivalent to that of CycleGAN, which requires images from approximately 30 patients for training. Findings demonstrated improvement of CBCT image quality using only the target CBCT images and the paired treatment planning CT images.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyQuality ImprovementProstatic NeoplasmsImage Processing, Computer-AssistedHumansMaleSignal-To-Noise RatioDeep LearningRadiotherapy Planning, Computer-Assisted

Stichwörter der Autor:innen

Cone beam CTDeep learningDeformable image registrationOne-shot learningSuper-resolution

Autor:innen und Institutionen

  • Graduate School of Medical Care and Technology, Teikyo University, 2-11-1 Kaga, Itabashi-Ku, Tokyo, 173-8605, Japan.
  • Department of Radiology, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-Ku, Tokyo, 113-8655, Japan.
  • Health Care Division, Health and Counseling Center, Osaka University, 1 Machikaneyamatyo, Toyonaka-Shi, Osaka, 560-0043, Japan.
  • Central of Radiology, Teikyo University Hospital, 2-11-1 Kaga, Itabashi-Ku, Tokyo, 173-8606, Japan.
  • Department of Radiology, Teikyo University School of Medicine, 2-11-1 Kaga, Itabashi-Ku, Tokyo, 173-8605, Japan.
  • Graduate School of Medical Care and Technology, Teikyo University, 2-11-1 Kaga, Itabashi-Ku, Tokyo, 173-8605, Japan. kotoku@med.teikyo-u.ac.jp.

Förderung

  • Japan Society for the Promotion of Science
  • Japan Science and Technology Agency

Zitieren

APA

Tsuji, T., Yoshida, S., Hommyo, M., Oyama, A., Kumagai, S., Shiraishi, K., & Kotoku, J. (2024). Cone Beam Computed Tomography Image-Quality Improvement Using “One-Shot” Super-resolution. Journal of Imaging Informatics in Medicine. https://doi.org/10.1007/s10278-024-01346-w

Vancouver

Tsuji T, Yoshida S, Hommyo M, Oyama A, Kumagai S, Shiraishi K, et al. Cone Beam Computed Tomography Image-Quality Improvement Using “One-Shot” Super-resolution. Journal of Imaging Informatics in Medicine. 2024. doi:10.1007/s10278-024-01346-w

BibTeX
@article{Tsuji2024,
  author = {Tsuji, Takumasa and Yoshida, Soichiro and Hommyo, Mitsuki and Oyama, Asuka and Kumagai, Shinobu and Shiraishi, Kenshiro and Kotoku, Jun'ichi},
  title = {Cone Beam Computed Tomography Image-Quality Improvement Using “One-Shot” Super-resolution},
  journal = {Journal of Imaging Informatics in Medicine},
  year = {2024},
  doi = {10.1007/s10278-024-01346-w}
}
Kostenlos starten →