Inter-fractional error and intra-fractional motion of prostate and dosimetry comparisons of patient position registrations with versus without fiducial markers during treatment with carbon-ion radiotherapy
Radiological Physics and Technology · 2024
DOI: 10.1007/s12194-024-00808-8 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Radiological Physics and Technology, 2024. Verfasst von Yuma Iwai und 10 weiteren Autor:innen. Beteiligte Einrichtung: National Institutes for Quantum Science and Technology, QST Hospital, Chiba, Japan. Hauptthemen laut MEDLINE: Fiducial Markers, Prostatic Neoplasms, Patient Positioning, Heavy Ion Radiotherapy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Grants-in-Aid for Scientific Researc, Grants‐in‐Aid for Scientific Researc.
Abstract (Originalsprache)
A few reports have discussed the influence of inter-fractional position error and intra-fractional motion on dose distribution, particularly regarding a spread-out Bragg peak. We investigated inter-fractional and intra-fractional prostate position error by monitoring fiducial marker positions. In 2020, data from 15 patients with prostate cancer who received carbon-ion beam radiotherapy (CIRT) with gold markers were investigated. We checked marker positions before and during irradiation to calculate the inter-fractional positioning and intra-fractional movement and evaluated the CIRT dose distribution by adjusting the planning beam isocenter and clinical target volume (CTV) position. We compared the CTV dose coverages (CTV receiving 95% [V95%] or 98% [V98%] of the prescribed dose) between skeletal and fiducial matching irradiation on the treatment planning system. For inter-fractional error, the mean distance between the marker position in the planning images and that in a patient starting irradiation with skeletal matching was 1.49 ± 1.11 mm (95th percentile = 1.85 mm). The 95th percentile (maximum) values of the intra-fractional movement were 0.79 mm (2.31 mm), 1.17 mm (2.48 mm), 1.88 mm (4.01 mm), 1.23 mm (3.00 mm), and 2.09 mm (8.46 mm) along the lateral, inferior, superior, dorsal, and ventral axes, respectively. The mean V95% and V98% were 98.2% and 96.2% for the skeletal matching plan and 99.5% and 96.8% for the fiducial matching plan, respectively. Fiducial matching irradiation improved the CTV dose coverage compared with skeletal matching irradiation for CIRT for prostate cancer.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Institutes for Quantum Science and Technology, QST Hospital, Chiba, Japan.
- Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology, Chiba, 263-8555, Japan. mori.shinichiro@qst.go.jp.
- Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology, Chiba, 263-8555, Japan.
- Department of Radiology, Chiba University Hospital, Chiba, Japan.
Förderung
- Grants-in-Aid for Scientific Researc
- Grants‐in‐Aid for Scientific Researc
Zitieren
APA
Iwai, Y., Mori, S., Ishikawa, H., Kanematsu, N., Matsumoto, S., Nakaji, T., Okonogi, N., Kobayashi, K., Wakatsuki, M., Uno, T., & Yamada, S. (2024). Inter-fractional error and intra-fractional motion of prostate and dosimetry comparisons of patient position registrations with versus without fiducial markers during treatment with carbon-ion radiotherapy. Radiological Physics and Technology. https://doi.org/10.1007/s12194-024-00808-8
Vancouver
Iwai Y, Mori S, Ishikawa H, Kanematsu N, Matsumoto S, Nakaji T, et al. Inter-fractional error and intra-fractional motion of prostate and dosimetry comparisons of patient position registrations with versus without fiducial markers during treatment with carbon-ion radiotherapy. Radiological Physics and Technology. 2024. doi:10.1007/s12194-024-00808-8
BibTeX
@article{Iwai2024,
author = {Iwai, Yuma and Mori, Shinichiro and Ishikawa, Hitoshi and Kanematsu, Nobuyuki and Matsumoto, Shinnosuke and Nakaji, Taku and Okonogi, Noriyuki and Kobayashi, Kana and Wakatsuki, Masaru and Uno, Takashi and Yamada, Shigeru},
title = {Inter-fractional error and intra-fractional motion of prostate and dosimetry comparisons of patient position registrations with versus without fiducial markers during treatment with carbon-ion radiotherapy},
journal = {Radiological Physics and Technology},
year = {2024},
doi = {10.1007/s12194-024-00808-8}
}
EUVIMED