EUVIMEDEUVIMED entdecken
Crossref

Assessment of the deep learning-based gamma passing rate prediction system for 1.5 T magnetic resonance-guided linear accelerator

Ryota Tozuka, Noriyuki Kadoya, Kazuhiro Arai, Kiyokazu Sato, Keiichi Jingu

Radiological Physics and Technology · 2024

DOI: 10.1007/s12194-024-00800-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiological Physics and Technology, 2024. Verfasst von Ryota Tozuka und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan. Hauptthemen laut MEDLINE: Deep Learning, Particle Accelerators, Magnetic Resonance Imaging, Radiotherapy, Image-Guided. Die Arbeit nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Measurement-based verification is impossible for the patient-specific quality assurance (QA) of online adaptive magnetic resonance imaging-guided radiotherapy (oMRgRT) because the patient remains on the couch throughout the session. We assessed a deep learning (DL) system for oMRgRT to predict the gamma passing rate (GPR). This study collected 125 verification plans [reference plan (RP), 100; adapted plan (AP), 25] from patients with prostate cancer treated using Elekta Unity. Based on our previous study, we employed a convolutional neural network that predicted the GPRs of nine pairs of gamma criteria from 1%/1 mm to 3%/3 mm. First, we trained and tested the DL model using RPs (n = 75 and n = 25 for training and testing, respectively) for its optimization. Second, we tested the GPR prediction accuracy using APs to determine whether the DL model could be applied to APs. The mean absolute error (MAE) and correlation coefficient (r) of the RPs were 1.22 ± 0.27% and 0.29 ± 0.10 in 3%/2 mm, 1.35 ± 0.16% and 0.37 ± 0.15 in 2%/2 mm, and 3.62 ± 0.55% and 0.32 ± 0.14 in 1%/1 mm, respectively. The MAE and r of the APs were 1.13 ± 0.33% and 0.35 ± 0.22 in 3%/2 mm, 1.68 ± 0.47% and 0.30 ± 0.11 in 2%/2 mm, and 5.08 ± 0.29% and 0.15 ± 0.10 in 1%/1 mm, respectively. The time cost was within 3 s for the prediction. The results suggest the DL-based model has the potential for rapid GPR prediction in Elekta Unity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningParticle AcceleratorsMagnetic Resonance ImagingRadiotherapy, Image-GuidedProstatic NeoplasmsHumansMaleRadiotherapy Planning, Computer-AssistedGamma Rays

Stichwörter der Autor:innen

Deep learningMR-LinacOnline ARTPatient QAProstateUnity

Autor:innen und Institutionen

  • Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan.
  • Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan. kadoya.n@rad.med.tohoku.ac.jp.
  • Department of Radiation Technology, Tohoku University Hospital, Sendai, Japan.

Zitieren

APA

Tozuka, R., Kadoya, N., Arai, K., Sato, K., & Jingu, K. (2024). Assessment of the deep learning-based gamma passing rate prediction system for 1.5 T magnetic resonance-guided linear accelerator. Radiological Physics and Technology. https://doi.org/10.1007/s12194-024-00800-2

Vancouver

Tozuka R, Kadoya N, Arai K, Sato K, Jingu K. Assessment of the deep learning-based gamma passing rate prediction system for 1.5 T magnetic resonance-guided linear accelerator. Radiological Physics and Technology. 2024. doi:10.1007/s12194-024-00800-2

BibTeX
@article{Tozuka2024,
  author = {Tozuka, Ryota and Kadoya, Noriyuki and Arai, Kazuhiro and Sato, Kiyokazu and Jingu, Keiichi},
  title = {Assessment of the deep learning-based gamma passing rate prediction system for 1.5 T magnetic resonance-guided linear accelerator},
  journal = {Radiological Physics and Technology},
  year = {2024},
  doi = {10.1007/s12194-024-00800-2}
}
Kostenlos starten →