Simultaneous transapical transcatheter aortic and mitral valve replacement in patients with severe valve dysfunction: initial experience
General Thoracic and Cardiovascular Surgery · 2024
DOI: 10.1007/s11748-024-02026-w ↗Kurz gefasst
Fachartikel in der Zeitschrift General Thoracic and Cardiovascular Surgery, 2024. Verfasst von Jiawei Zhou und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Road, Chaoyang District, Beijing, 100029, China. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Mitral Valve, Heart Valve Prosthesis Implantation, Aortic Valve. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Gefördert von: National Key R&D Program of China.
Abstract (Originalsprache)
BACKGROUND: Simultaneous transcatheter mitral valve in valve (VIV) replacement and aortic valve replacement experience is limited. We report our initial experience with simultaneous transapical transcatheter aortic and mitral valve replacement in patients with severe valve dysfunction. METHODS: A total of 8 patients had simultaneous transcatheter heart valve implants for severe mitral bioprosthesis failure (VIV), with a second valve procedure that included native aortic regurgitation (n = 3) or degenerated bioprostheses in the aortic position (n = 5). All patients were treated with a self-expandable J-valve transcatheter valve, using the transapical approach. RESULTS: The mean age of the patients was 73.1 ± 6.2 years. The mean Society of Thoracic Surgeons score was 13.8 ± 6.3%. Device success was 100% according to Valve Academic Research Consortium-2 criteria. No other procedure-associated complications occurred, including left ventricular outflow tract obstruction and valve migration. The mean hospital lengths of stay after the procedure were 11.5 ± 8.0 days. No deaths occurred at 30 days. At a median follow-up period of 28.7 ± 22.3 months, no patients died. All patients were in New York Heart Association functional classes I-II. Echocardiographic parameters at follow-up showed a normofunctioning J valve in the mitral position and a mean max mitral flow velocity of 2.0 ± 0.5 m/s; the J valve in the aortic position was also normofunctioning, and the mean max aortic flow velocity was 2.3 ± 0.5 m/s. CONCLUSION: Simultaneous transapical transcatheter aortic and mitral valve replacement using the self-expandable J valve appears to be a feasible and effective alternative to redo surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Road, Chaoyang District, Beijing, 100029, China.
- Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Road, Chaoyang District, Beijing, 100029, China. zhanghb2318@163.com.
Förderung
- National Key R&D Program of China
Zitieren
APA
Zhou, J., Li, Y., Wang, J., & Zhang, H. (2024). Simultaneous transapical transcatheter aortic and mitral valve replacement in patients with severe valve dysfunction: initial experience. General Thoracic and Cardiovascular Surgery. https://doi.org/10.1007/s11748-024-02026-w
Vancouver
Zhou J, Li Y, Wang J, Zhang H. Simultaneous transapical transcatheter aortic and mitral valve replacement in patients with severe valve dysfunction: initial experience. General Thoracic and Cardiovascular Surgery. 2024. doi:10.1007/s11748-024-02026-w
BibTeX
@article{Zhou2024,
author = {Zhou, Jiawei and Li, Yuehuan and Wang, JianGang and Zhang, Haibo},
title = {Simultaneous transapical transcatheter aortic and mitral valve replacement in patients with severe valve dysfunction: initial experience},
journal = {General Thoracic and Cardiovascular Surgery},
year = {2024},
doi = {10.1007/s11748-024-02026-w}
}
EUVIMED