Kurz gefasst

Fachartikel in der Zeitschrift Journal of Robotic Surgery, online erschienen am 20.08.2026. Verfasst von Rafał Bogdan Drobot. Beteiligte Einrichtung: Urology Department, Institute of Medical Sciences, Faculty of Medicine, Collegium Medicum, Cardinal Stefan Wyszyński University in Warsaw, Bursztynow…. Hauptthemen laut MEDLINE: United States Food and Drug Administration, Robotic Surgical Procedures, Equipment Failure, Medical Device Recalls. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

FDA recall records document corrections and removals; however, product naming, administrative root-cause descriptors, and the functional mechanisms underlying failure are not interchangeable. Accordingly, the affected assets, functional loci, failure modes, and requested actions were characterized in recalls involving soft-tissue surgical robotic systems. A retrospective cohort was constructed from the US Food and Drug Administration (FDA) Medical Device Recall Database and openFDA through 17 July 2026. Eligible product records were deduplicated by FDA product-record identifier and grouped by recall-event identifier. Every event underwent full-text narrative adjudication on two separate axes: the asset explicitly listed in the recalled product and the functional locus implicated by the product, recall-reason, and corrective-action text. A prespecified evidence hierarchy assigned one of eight primary failure modes; verbatim FDA root-cause descriptors were retained separately. Analyses were descriptive. Of 281 candidate product records, 274 were eligible and represented 120 unique recall events. Listed assets were instruments/accessories in 56 events (46.7%), core systems in 52 (43.3%), labeling/instructions for use in eight (6.7%), and multiple layers in four (3.3%). Adjudicated functional loci were core system (50; 41.7%), instrument/accessory (44; 36.7%), labeling/operational (16; 13.3%), and cross-layer interface (10; 8.3%). Primary failure modes were mechanical/material integrity (48; 40.0%), labeling/IFU/regulatory (16; 13.3%), software/control logic (15; 12.5%), electrical/electronic/power (13; 10.8%), process/use/maintenance (12; 10.0%), sterility/packaging (nine; 7.5%), indeterminate/mixed (six; 5.0%), and cybersecurity configuration (one; 0.8%). The Versius Secure Boot event was the sole recall with an explicit cybersecurity mechanism. The median initiation-to-posting interval was 33 days (interquartile range 22-111; n = 91). Surgical-robot recalls span mechanical, electrical, software, informational, and security-control failures. Separating the recalled asset from the functional failure locus, and both from the FDA root-cause descriptor, prevents an error message or administrative software label from being treated as proof of a software defect. These US regulatory data describe corrective actions, not clinical incidence or comparative platform safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

United States Food and Drug AdministrationRobotic Surgical ProceduresEquipment FailureMedical Device RecallsUnited StatesHumansRetrospective StudiesCohort Studies

Stichwörter der Autor:innen

CybersecurityFailure modeMedical device recallPostmarket surveillanceRobotic surgerySecure BootSoftware

Autor:innen und Institutionen

  • Urology Department, Institute of Medical Sciences, Faculty of Medicine, Collegium Medicum, Cardinal Stefan Wyszyński University in Warsaw, Bursztynowa 2, 04-749, Warsaw, Poland. r.drobot@uksw.edu.pl.
  • Department of Urology and Urological Oncology, Multidisciplinary Hospital in Warsaw-Międzylesie, Bursztynowa 2, 04-749, Warsaw, Poland. r.drobot@uksw.edu.pl.
  • EAU Young Academic Urologists Robotics in Urology Working Group, Arnhem, The Netherlands. r.drobot@uksw.edu.pl.

Zitieren

APA

Drobot, R. B. (2026). Failure modes in soft-tissue surgical robots: an adjudicated FDA recall cohort, 2005–2026. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-026-03818-3

Vancouver

Drobot RB. Failure modes in soft-tissue surgical robots: an adjudicated FDA recall cohort, 2005–2026. Journal of Robotic Surgery. 2026;20(1). doi:10.1007/s11701-026-03818-3

BibTeX
@article{Drobot2026,
  author = {Drobot, Rafał Bogdan},
  title = {Failure modes in soft-tissue surgical robots: an adjudicated FDA recall cohort, 2005–2026},
  journal = {Journal of Robotic Surgery},
  year = {2026},
  volume = {20},
  number = {1},
  doi = {10.1007/s11701-026-03818-3}
}
Kostenlos starten →