EUVIMEDEUVIMED entdecken
Vergleichsstudie

Adverse-event reporting profiles of the Intuitive SureForm robotic stapling system in the FDA MAUDE database differ by product code: a comparison of GDW- and NAY-coded reports

Qi Xu, Xiaohui Chen, Yuwan Gao, Ou Zhang

Journal of Robotic Surgery · 20.07.2026 · 20 (1)

DOI: 10.1007/s11701-026-03681-2 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Robotic Surgery, online erschienen am 20.07.2026. Verfasst von Qi Xu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, The First Affiliated Hospital of Nanyang Medical College, Nanyang, China. Cookies_white@outlook.com. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Databases, Factual, Surgical Stapling, Product Surveillance, Postmarketing. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: Self-funded Scientific Research Project for Western Medicine of the Guangxi Zhuang Autonomous Region Health Commission, Nanyang Science and Technology Information Network.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Prior MAUDE studies of robotic surgery have largely characterized platform-level or procedure-specific adverse-event profiles, whereas subsystem-level surveillance of robotic stapling devices remains limited. Robotic stapling systems are multi-component devices, and post-market adverse-event reports may be distributed across separate regulatory product codes for stapler instruments and reloads. We conducted a retrospective, product-code-aware database study of Intuitive Surgical SureForm-related reports in the U.S. Food and Drug Administration Manufacturer and User Facility Device Experience database received from October 11, 2018, through March 31, 2026. Deduplicated reports were grouped by primary product code and reviewed using prespecified narrative labels for clinical consequences and failure modes. The cohort included 2,802 reports, with annual volume increasing from 7 reports in 2018 to 654 in 2025. Product-code profiles differed markedly: GDW-coded reports were predominantly Injury reports (1,336/1,912; 69.9%), whereas NAY-coded reports were predominantly Malfunction reports (718/883; 81.3%). Narrative labels also differed: bleeding, leak, tissue-pushout, misfire, and conversion terms were more frequent in GDW-coded reports, whereas stuck, jam, or freeze terminology was more frequent in NAY-coded reports. Staple-line issue was identified more frequently in GDW-coded reports but showed lower reproducibility in validation analyses and was therefore interpreted cautiously. Death-term screening identified device-specific false positives arising from technical use of “force expired.” These findings show that product-code assignment can shape the observable safety profile of a robotic stapling subsystem and suggest hypothesis-generating surveillance priorities, including product-code-integrated queries, narrative screening, and device-specific review of recurrent report-text patterns.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresDatabases, FactualSurgical StaplingProduct Surveillance, PostmarketingSurgical StaplersUnited StatesUnited States Food and Drug AdministrationHumansRetrospective StudiesEquipment Failure

Stichwörter der Autor:innen

Adverse event reportingMAUDE databasePost-market surveillanceRobotic staplingRobotic surgerySureForm

Autor:innen und Institutionen

  • Department of Surgery, The First Affiliated Hospital of Nanyang Medical College, Nanyang, China. Cookies_white@outlook.com.
  • Center for Clinical Epidemiology and Medical Data Science, The First Affiliated Hospital of Nanyang Medical College, Nanyang, China. Cookies_white@outlook.com.
  • Department of Surgery, Nanyang Central Hospital, Nanyang, China. Cookies_white@outlook.com.
  • Department of Breast and Thyroid Surgery, The Second Affiliated Hospital of Guilin Medical University, Guilin, China.
  • Department of Science and Education, The First Affiliated Hospital of Nanyang Medical College, Nanyang, China.
  • The First Affiliated Hospital of Nanyang Medical College, Nanyang, China.

Förderung

  • Self-funded Scientific Research Project for Western Medicine of the Guangxi Zhuang Autonomous Region Health Commission
  • Nanyang Science and Technology Information Network

Zitieren

APA

Xu, Q., Chen, X., Gao, Y., & Zhang, O. (2026). Adverse-event reporting profiles of the Intuitive SureForm robotic stapling system in the FDA MAUDE database differ by product code: a comparison of GDW- and NAY-coded reports. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-026-03681-2

Vancouver

Xu Q, Chen X, Gao Y, Zhang O. Adverse-event reporting profiles of the Intuitive SureForm robotic stapling system in the FDA MAUDE database differ by product code: a comparison of GDW- and NAY-coded reports. Journal of Robotic Surgery. 2026;20(1). doi:10.1007/s11701-026-03681-2

BibTeX
@article{Xu2026,
  author = {Xu, Qi and Chen, Xiaohui and Gao, Yuwan and Zhang, Ou},
  title = {Adverse-event reporting profiles of the Intuitive SureForm robotic stapling system in the FDA MAUDE database differ by product code: a comparison of GDW- and NAY-coded reports},
  journal = {Journal of Robotic Surgery},
  year = {2026},
  volume = {20},
  number = {1},
  doi = {10.1007/s11701-026-03681-2}
}
Kostenlos starten →