EUVIMEDEUVIMED entdecken
Scoping ReviewOpen Access · CC BY-NC-ND 4.0

Beyond rewarming time: graft thermometry and cooling technologies in robot-assisted kidney transplantation—a scoping review

Rafał Bogdan Drobot, Kacper Kubista, Jakub Miłoszewski

Journal of Robotic Surgery · 2026

DOI: 10.1007/s11701-026-03804-9 ↗

Kurz gefasst

Scoping Review in der Zeitschrift Journal of Robotic Surgery, 2026. Verfasst von Rafał Bogdan Drobot und 2 weiteren Autor:innen. Beteiligte Einrichtung: Urology Department, Institute of Medical Sciences, Faculty of Medicine, Collegium Medicum, Cardinal Stefan Wyszyński University in Warsaw, Bursztynow…. Hauptthemen laut MEDLINE: Kidney Transplantation, Robotic Surgical Procedures, Thermometry, Rewarming. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Robot-assisted kidney transplantation (RAKT) converts vascular anastomosis time into an incompletely measured thermal exposure. We mapped how grafts are cooled and how temperature is measured, reported, and linked to outcomes during RAKT. Following a prespecified protocol and a documented search-source amendment, PubMed/MEDLINE, Scopus, and Web of Science Core Collection were searched from inception to 26 July 2026; a backward and forward citation-chain audit was completed on 2 August 2026. Human or large-animal RAKT reports were eligible if they provided numeric intraoperative graft or pelvic thermometry or evaluated a purpose-built cooling system. Data were charted by report and innovation program. Clinical, technical, and measurement heterogeneity precluded meta-analysis. Reporting followed PRISMA-ScR. Seven reports from six innovation programs met eligibility criteria: five human studies, one porcine study, and one mixed bench-porcine-human development study. Six reports contained numeric graft or pelvic thermometry; one mesh-wrap report specified a target below 15 °C but did not measure graft temperature. Among continuous-cooling RAKT groups reporting mean ± SD thermometry, values ranged from 6.5 ± 3.1 °C at reperfusion in pigs to 19.74 ± 1.61 °C at 65 min in a matched human cohort; regional ice-based clinical series reported mean pre-reperfusion surface temperatures of 20.1-22.5 °C. Only two reports explicitly specified both a precise anatomical measurement site and a sampling interval.No study validated a clinically actionable threshold or an adjusted temperature-outcome relationship. Observed thermometry in six reports demonstrates that hypothermic conditions can be achieved under specific cooled RAKT protocols, but evidence of target attainment does not extend to the device-intent-only report and comparative clinical effectiveness remains unproven. Elapsed rewarming time should not substitute for graft thermal exposure. Standardized sensor metadata, serial temperatures, and temperature-dose metrics are prerequisites for comparative trials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Kidney TransplantationRobotic Surgical ProceduresThermometryRewarmingHypothermia, InducedHumansAnimalsSwineTime FactorsAnastomosis, SurgicalKidney

Stichwörter der Autor:innen

Hypothermia, InducedIschemia-Reperfusion InjuryKidney transplantationRewarmingRobotic surgical proceduresTemperature

Autor:innen und Institutionen

  • Urology Department, Institute of Medical Sciences, Faculty of Medicine, Collegium Medicum, Cardinal Stefan Wyszyński University in Warsaw, Bursztynowa 2, Warsaw, 04-749, Poland. r.drobot@uksw.edu.pl.
  • Department of Urology and Urological Oncology, Multidisciplinary Hospital in Warsaw - Międzylesie, Bursztynowa 2, Warsaw, 04-749, Poland. r.drobot@uksw.edu.pl.
  • EAU YAU Robotics in Urology Working Group Affiliate Member, Arnhem, The Netherlands. r.drobot@uksw.edu.pl.
  • Department of Urology and Urological Oncology, Multidisciplinary Hospital in Warsaw - Międzylesie, Bursztynowa 2, Warsaw, 04-749, Poland.

Zitieren

APA

Drobot, R. B., Kubista, K., & Miłoszewski, J. (2026). Beyond rewarming time: graft thermometry and cooling technologies in robot-assisted kidney transplantation—a scoping review. Journal of Robotic Surgery. https://doi.org/10.1007/s11701-026-03804-9

Vancouver

Drobot RB, Kubista K, Miłoszewski J. Beyond rewarming time: graft thermometry and cooling technologies in robot-assisted kidney transplantation—a scoping review. Journal of Robotic Surgery. 2026. doi:10.1007/s11701-026-03804-9

BibTeX
@article{Drobot2026,
  author = {Drobot, Rafał Bogdan and Kubista, Kacper and Miłoszewski, Jakub},
  title = {Beyond rewarming time: graft thermometry and cooling technologies in robot-assisted kidney transplantation—a scoping review},
  journal = {Journal of Robotic Surgery},
  year = {2026},
  doi = {10.1007/s11701-026-03804-9}
}
Kostenlos starten →