Transoral robotic surgery using the da Vinci single-port system: current evidence and clinical indications – a systematic review and meta-analysis
Journal of Robotic Surgery · 12.06.2026 · 20 (1)
DOI: 10.1007/s11701-026-03540-0 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Journal of Robotic Surgery, online erschienen am 12.06.2026. Verfasst von Tobias Niederegger und 7 weiteren Autor:innen. Beteiligte Einrichtung: Medical Faculty, University of Heidelberg, Heidelberg, Germany. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Head and Neck Neoplasms, Natural Orifice Endoscopic Surgery. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Freiburg.
Abstract (Originalsprache)
The DaVinci Single-Port (SP) transoral robotic surgery (TORS) platform was developed to overcome spatial constraints and instrument collisions encountered with multiport systems in head and neck surgery. We systematically reviewed and meta-analyzed perioperative performance, safety, functional recovery, and oncologic outcomes of SP TORS. Following PRISMA 2020, we searched PubMed/MEDLINE, Embase, Cochrane Library, Web of Science, and the first 25 pages of Google Scholar through January 1, 2026. Peer-reviewed English-language clinical and cadaveric studies evaluating SP TORS were included. Three reviewers screened studies and extracted data. Random-effects meta-analyses were performed where appropriate. Fourteen studies (2019–2025) including 479 patients met inclusion criteria. Patient-level evidence was concentrated in oncologic cohorts, with additional smaller clinical applications in obstructive sleep apnoea-related tongue-base surgery (37 patients), hypopharyngeal foreign body removal (1 patient), parapharyngeal space surgery (2 patients), and SP-assisted reconstruction (3 patients), as well as preclinical feasibility studies. No study reported intraoperative conversion to multiport or open surgery. Pooled estimates were console time 60.04 min (95% CI 29.56–90.51; I² = 99.1%), docking time 10.13 min (0.47–19.79; I² = 97.9%), operative time 57.72 min (37.23–78.21; I² = 0.0%), length of stay 10.63 days (2.43–18.82; I² = 99.8%), and blood loss 24.16 mL (− 6.95 to 55.27; I² = 86.8%). Bleeding was the most consistently reported surgical complication, with major bleeding requiring operative management reported in larger cohorts but remaining uncommon. Functional recovery suggested early oral intake, although timing was inconsistently reported. Margin status was predominantly R0 in several oncologic cohorts, although one matched cohort reported a lower R0 rate. SP TORS appears feasible across indications, but current evidence is limited by nonrandomized designs, inconsistent long-term reporting, and between-study heterogeneity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Faculty, University of Heidelberg, Heidelberg, Germany.
- Department of Surgery, College of Medicine, University of Warith Al-Anbiyaa, Karbala, 56001, Iraq. murtaja.satea@gmail.com.
- Division of Plastic Surgery, Microsurgery and Regenerative Medicine Laboratory, University of Wisconsin School of Medicine and Public Health, 600 Highland Avenue, Madison, WI, 53705, USA. murtaja.satea@gmail.com.
- Department of Otolaryngology, Head and Neck Surgery, TUM School of Medicine and Health, Technical University of Munich (TUM), Munich, Germany.
- Department of Hand, Plastic and Reconstructive Surgery, Burn Trauma Center, BG Trauma Center Ludwigshafen, University of Heidelberg, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany.
- Department of Oral and Maxillofacial Surgery, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
Förderung
- Universitätsklinikum Freiburg
Zitieren
APA
Niederegger, T., Karakas, E., Satea, M., Hoch, C. C., Hundeshagen, G., Knoedler, L., Metzger, M. C., & Wüster, J. (2026). Transoral robotic surgery using the da Vinci single-port system: current evidence and clinical indications – a systematic review and meta-analysis. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-026-03540-0
Vancouver
Niederegger T, Karakas E, Satea M, Hoch CC, Hundeshagen G, Knoedler L, et al. Transoral robotic surgery using the da Vinci single-port system: current evidence and clinical indications – a systematic review and meta-analysis. Journal of Robotic Surgery. 2026;20(1). doi:10.1007/s11701-026-03540-0
BibTeX
@article{Niederegger2026,
author = {Niederegger, Tobias and Karakas, Emre and Satea, Murtaja and Hoch, Cosima C and Hundeshagen, Gabriel and Knoedler, Leonard and Metzger, Marc-Christian and Wüster, Jonas},
title = {Transoral robotic surgery using the da Vinci single-port system: current evidence and clinical indications – a systematic review and meta-analysis},
journal = {Journal of Robotic Surgery},
year = {2026},
volume = {20},
number = {1},
doi = {10.1007/s11701-026-03540-0}
}
EUVIMED