Application and advantages of a joystick-controlled robotic scope holder in transoral endoscopic thyroidectomy vestibular approach: a comparative study
Updates in Surgery · 2024
DOI: 10.1007/s13304-024-01783-w ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Updates in Surgery, 2024. Verfasst von Suo-Hsien Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Surgery, Chang Gung Memorial Hospital, No. 222, Maijin Rd., Anle Dist., Keelung, 204, Taiwan. Hauptthemen laut MEDLINE: Thyroidectomy, Robotic Surgical Procedures, Operative Time, Natural Orifice Endoscopic Surgery. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
Transoral endoscopic thyroidectomy has gained popularity due to its scarless nature, but the use of a handheld endoscope can lead to an unstable visual field. Soloassist II, a robotic scope holder, enables precise control using a joystick, ensuring stable vision. This study aims to evaluate the application and the advantages of Soloassist II in transoral thyroidectomy. Patients who underwent transoral thyroidectomy with Soloassist II or human assistance between June 2019 and May 2021 were reviewed. Patient demographics and surgical outcomes were compared. The ergonomic stress of the assistant in both groups was also measured. A total of 100 consecutive patients were included: 32 were assisted by Soloassist II and 68 by humans. The Soloassist II group demonstrated significantly shorter operation times (median [IQR]) (165 [149,179] vs. 181 [165,204] min, P = 0.004) in unilateral lobectomy and less blood loss (median [IQR]) (2 [2,2] vs. 2 [2,3] ml, P = 0.002) than the human-assisted group. Postoperative course and complication rates were similar. The musculoskeletal pain of the assistant was significantly higher and involved more areas in the human-assisted group. The utilization of Soloassist II in transoral endoscopic thyroidectomy is easy to set up and leads to shorter operation times, reduced blood loss, and decreased musculoskeletal pain compared to human handheld endoscope. These findings support the potential of Soloassist II in improving surgical outcomes and minimizing physical strain during transoral thyroidectomy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of General Surgery, Chang Gung Memorial Hospital, No. 222, Maijin Rd., Anle Dist., Keelung, 204, Taiwan.
- Division of Endocrinology and Metabolism, Department of Internal Medicine, Chang Gung Memorial Hospital, Chang Gung University, Keelung, Taiwan.
- Department of General Surgery, Chang Gung Memorial Hospital, No. 222, Maijin Rd., Anle Dist., Keelung, 204, Taiwan. capitatecapitate@gmail.com.
Zitieren
APA
Wang, S. H., Hsieh, T. H., Chao, W. P., Lo, T. Y., Huang, T. S., & Chen, Y. H. (2024). Application and advantages of a joystick-controlled robotic scope holder in transoral endoscopic thyroidectomy vestibular approach: a comparative study. Updates in Surgery. https://doi.org/10.1007/s13304-024-01783-w
Vancouver
Wang SH, Hsieh TH, Chao WP, Lo TY, Huang TS, Chen YH. Application and advantages of a joystick-controlled robotic scope holder in transoral endoscopic thyroidectomy vestibular approach: a comparative study. Updates in Surgery. 2024. doi:10.1007/s13304-024-01783-w
BibTeX
@article{Wang2024,
author = {Wang, Suo-Hsien and Hsieh, Tsai-Heng and Chao, Wu-Po and Lo, Ta-You and Huang, Ting-Shuo and Chen, Yu-Hsien},
title = {Application and advantages of a joystick-controlled robotic scope holder in transoral endoscopic thyroidectomy vestibular approach: a comparative study},
journal = {Updates in Surgery},
year = {2024},
doi = {10.1007/s13304-024-01783-w}
}
EUVIMED