A novel robot-assisted flexible ureteroscope system(RAFUS): design, learning curve, ergonomics, and preclinical feasibility
Journal of Robotic Surgery · 23.05.2026 · 20 (1)
DOI: 10.1007/s11701-026-03490-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Robotic Surgery, online erschienen am 23.05.2026. Verfasst von Anjun Zhou und 7 weiteren Autor:innen. Beteiligte Einrichtung: Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China. Hauptthemen laut MEDLINE: Learning Curve, Ergonomics, Ureteroscopes, Robotic Surgical Procedures. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Jilin University Concept Validation Project, Jilin Provincial Scientific and Technological Development Program.
Abstract (Originalsprache)
Traditional manual flexible ureteroscopy imposes a steep learning curve and severe ergonomic burdens. Furthermore, many existing robotic systems lack integrated optical fiber manipulation. To overcome these limitations, this paper presents the design and evaluation of a novel RAFUS that achieves precise control over four key degrees of freedom, including automated laser fiber delivery, via a miniaturized operating handle. For systematic evaluation via an integrated experimental platform, learning curve analysis was conducted, and a novel mean amplitude spectral density (MASD) metric was combined with Mean Frequency (MNF) to form a robust joint index for ergonomic assessment, followed by in vivo preclinical validation. Experimental results based on an exponential learning model demonstrate that the RAFUS not only significantly shortens the learning curve but also minimizes inter-operator variance, reducing the average exploration time from 435 ± 186.6s to 272 ± 69.9s. With the MASD metric effectively overcoming involuntary mechanical unloading and physiological micro-tremors, the joint evaluation demonstrated severe asymmetric fatigue in manual operations, primarily stressing the bilateral wrists and the right biceps brachii, evidenced by a 17.15% MNF decrease in the latter. Conversely, the robotic mode offers operators improved ergonomics. Finally, in vivo canine renal explorations successfully validated the safety and diagnostic reliability of the device. The proposed RAFUS shortens the learning curve and improves ergonomics, demonstrating potential for clinical translation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China.
- University of Chinese Academy of Sciences, Beijing, 100049, China.
- Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China. lihang@ciomp.ac.cn.
- Department of Urology, First Hospital of Jilin University, Changchun, China. wangyanb@jlu.edu.cn.
Förderung
- Jilin University Concept Validation Project
- Jilin Provincial Scientific and Technological Development Program
Zitieren
APA
Zhou, A., Xu, Z., Yu, P., Zhang, B., Mao, A., Man, G., Li, H., & Wang, Y. (2026). A novel robot-assisted flexible ureteroscope system(RAFUS): design, learning curve, ergonomics, and preclinical feasibility. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-026-03490-7
Vancouver
Zhou A, Xu Z, Yu P, Zhang B, Mao A, Man G, et al. A novel robot-assisted flexible ureteroscope system(RAFUS): design, learning curve, ergonomics, and preclinical feasibility. Journal of Robotic Surgery. 2026;20(1). doi:10.1007/s11701-026-03490-7
BibTeX
@article{Zhou2026,
author = {Zhou, Anjun and Xu, Zhenbang and Yu, Peng and Zhang, Bohan and Mao, Along and Man, Gang and Li, Hang and Wang, Yanbo},
title = {A novel robot-assisted flexible ureteroscope system(RAFUS): design, learning curve, ergonomics, and preclinical feasibility},
journal = {Journal of Robotic Surgery},
year = {2026},
volume = {20},
number = {1},
doi = {10.1007/s11701-026-03490-7}
}
EUVIMED