EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseVergleichsstudieOpen Access · CC BY 4.0

Clinical, functional, and radiological outcomes of robotic assisted versus conventional total hip arthroplasty: a systematic review and meta-analysis of randomized controlled trials

Pakpoom Ruangsomboon, Onlak Ruangsomboon, Khabab Osman, Daniel Pincus, Raman Mundi, Sebastian Tomescu, Bheeshma Ravi, Harman Chaudhry

Journal of Robotic Surgery · 2024

DOI: 10.1007/s11701-024-01949-z ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Robotic Surgery, 2024. Verfasst von Pakpoom Ruangsomboon und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Orthopaedic Surgery, Sunnybrook Health Sciences Centre, Toronto, ON, Canada. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Robotic Surgical Procedures, Randomized Controlled Trials as Topic, Osteoarthritis, Hip. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This systematic review of randomized controlled trials (RCTs) aims to compare important clinical, functional, and radiological outcomes between robotic-assisted total hip arthroplasty (RATHA) and conventional total hip arthroplasty (COTHA) in patients with hip osteoarthritis. We identified published RCTs comparing RATHA with COTHA in Ovid MEDLINE, EMBASE, Scopus, and Cochrane Library. Two reviewers independently performed study screening, risk of bias assessment and data extraction. Main outcomes were major complications, revision, patient-reported outcome measures (PROMs), and radiological outcomes. We included 8 RCTs involving 1014 patients and 977 hips. There was no difference in major complication rate (Relative Risk (RR) 0.78; 95% Confidence Interval (CI) 0.22 to 2.74), revision rate (RR 1.33; 95%CI 0.08 to 22.74), and PROMs (standardized mean difference 0.01; 95%CI − 0.27 to 0.30) between RATHA and COTHA. RATHA resulted in little to no effects on femoral stem alignment (mean difference (MD) − 0.57 degree; 95%CI − 1.16 to 0.03) but yielded overall lower leg length discrepancy (MD − 4.04 mm; 95%CI − 7.08 to − 1.0) compared to COTHA. Most combined estimates had low certainty of evidence mainly due to risk of bias, inconsistency, and imprecision. Based on the current evidence, there is no important difference in clinical and functional outcomes between RATHA and COTHA. The trivial higher radiological accuracy was also unlikely to be clinically meaningful. Regardless, more robust evidence is needed to improve the quality and strength of the current evidence. PROSPERO registration: the protocol was registered in the PROSPERO database (CRD42023453294). All methods were carried out in accordance with relevant guidelines and regulations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipRobotic Surgical ProceduresRandomized Controlled Trials as TopicOsteoarthritis, HipHumansTreatment OutcomePostoperative ComplicationsPatient Reported Outcome MeasuresReoperationRadiographyFemaleMale

Stichwörter der Autor:innen

ArthroplastyHipMeta-analysisRATHARoboticSystematic review

Autor:innen und Institutionen

  • Division of Orthopaedic Surgery, Sunnybrook Health Sciences Centre, Toronto, ON, Canada.
  • Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.
  • Institute of Health Policy, Management and Evaluation, University of Toronto, Toronto, ON, Canada.
  • Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand. doctor.mo@yahoo.com.
  • Upstream Lab, Li Ka Shing Knowledge Institute, MAP Centre for Urban Health Solutions, St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada. doctor.mo@yahoo.com.
  • Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, ON, Canada.

Zitieren

APA

Ruangsomboon, P., Ruangsomboon, O., Osman, K., Pincus, D., Mundi, R., Tomescu, S., Ravi, B., & Chaudhry, H. (2024). Clinical, functional, and radiological outcomes of robotic assisted versus conventional total hip arthroplasty: a systematic review and meta-analysis of randomized controlled trials. Journal of Robotic Surgery. https://doi.org/10.1007/s11701-024-01949-z

Vancouver

Ruangsomboon P, Ruangsomboon O, Osman K, Pincus D, Mundi R, Tomescu S, et al. Clinical, functional, and radiological outcomes of robotic assisted versus conventional total hip arthroplasty: a systematic review and meta-analysis of randomized controlled trials. Journal of Robotic Surgery. 2024. doi:10.1007/s11701-024-01949-z

BibTeX
@article{Ruangsomboon2024,
  author = {Ruangsomboon, Pakpoom and Ruangsomboon, Onlak and Osman, Khabab and Pincus, Daniel and Mundi, Raman and Tomescu, Sebastian and Ravi, Bheeshma and Chaudhry, Harman},
  title = {Clinical, functional, and radiological outcomes of robotic assisted versus conventional total hip arthroplasty: a systematic review and meta-analysis of randomized controlled trials},
  journal = {Journal of Robotic Surgery},
  year = {2024},
  doi = {10.1007/s11701-024-01949-z}
}
Kostenlos starten →