Recovery Time and Success: A Comparative Study of Robotic and Manual Total Hip Arthroplasty Outcomes
The Journal of Arthroplasty · 2025
DOI: 10.1016/j.arth.2025.01.031 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von Perry L Lim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts; Department of Orthopaedic Surgery, …. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Robotic Surgical Procedures, Osteoarthritis, Hip. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 71 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Despite the growing utilization of robotic-assisted total hip arthroplasty (rTHA), major debate remains regarding its comparative effectiveness in achieving optimal patient outcomes compared to manual total hip arthroplasty (mTHA). This study aimed to compare both the rate and time to achieve minimal clinically important difference (MCID) between rTHA and mTHA. METHODS: We conducted a retrospective analysis comparing 341 rTHAs with a 1:3 propensity score-matched cohort of 1,023 mTHAs performed from 2016 to 2022. Propensity scores were generated based on age, sex, body mass index, and Charlson comorbidity index. Patient-reported outcomes were evaluated using preoperative and postoperative scores of Patient-Reported Outcomes Measurement Information System (PROMIS) Global Physical, PROMIS Physical Function-10a (PF-10a), and Hip disability and Osteoarthritis Outcome Score - Physical Function Shortform (HOOS-PS). The time to achieve MCID was assessed using survival curves with and without interval censoring, and statistical comparisons were performed using log-rank and weighted log-rank tests. RESULTS: Manual total hip arthroplasty demonstrated a significantly higher rate of achieving MCID for PROMIS Global Physical (84.1 versus 79.8%, P = 0.003) and HOOS-PS (60.0 versus 44.9%, P < 0.001), while rates for PROMIS PF-10a were similar (58.6 versus 56.0%, P = 0.085). In the interval-censored analysis, rTHA achieved MCID for HOOS-PS significantly faster than mTHA (0.67 versus 1.0 months, P < 0.001). However, no significant differences were found for PROMIS Global Physical (0.24 versus 0.70 months, P = 0.18) and PROMIS PF-10a (1.60 versus 3.03 months, P = 0.73) when compared to mTHA. CONCLUSIONS: We conducted a propensity score-matched analysis of rTHA and mTHA, accounting for baseline characteristics, but not factors such as case difficulty and anatomic complexity. We found that rTHA achieved MCID faster, while mTHA had a higher overall proportion of MCID achievement. Robotic-assisted surgery may expedite initial recovery, while manual techniques may lead to better long-term outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts; Department of Orthopaedic Surgery, Newton-Wellesley Hospital, Newton, Massachusetts.
Zitieren
APA
Lim, P. L., Wang, K. Y., Sauder, N., Kumar, A. R., Bedair, H. S., & Melnic, C. M. (2025). Recovery Time and Success: A Comparative Study of Robotic and Manual Total Hip Arthroplasty Outcomes. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2025.01.031
Vancouver
Lim PL, Wang KY, Sauder N, Kumar AR, Bedair HS, Melnic CM. Recovery Time and Success: A Comparative Study of Robotic and Manual Total Hip Arthroplasty Outcomes. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2025.01.031
BibTeX
@article{Lim2025,
author = {Lim, Perry L and Wang, Kevin Y and Sauder, Nicholas and Kumar, Arun R and Bedair, Hany S and Melnic, Christopher M},
title = {Recovery Time and Success: A Comparative Study of Robotic and Manual Total Hip Arthroplasty Outcomes},
journal = {The Journal of Arthroplasty},
year = {2025},
doi = {10.1016/j.arth.2025.01.031}
}
EUVIMED