Universal non-circular cone beam CT orbits for metal artifact reduction imaging during image-guided procedures
Scientific Reports · 2024
DOI: 10.1038/s41598-024-77964-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Scientific Reports, 2024. Verfasst von Tess Reynolds und 6 weiteren Autor:innen. Beteiligte Einrichtung: University of Sydney, Sydney, Australia. tess.reynolds@sydney.edu.au. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Artifacts, Metals. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, Cancer Institute NSW, NIH HHS.
Abstract (Originalsprache)
Innovation in image-guided procedures has been driven by advances in robotic Cone Beam Computed Tomography (CBCT) systems. A fundamental challenge for CBCT imaging is metal artifacts arising from surgical tools and implanted hardware. Here, we outline how two universal non-circular imaging orbits, optimized for metal artifact reduction, can be implemented in real-time on clinical robotic CBCT systems. Demonstrating potential clinical utility, the universal orbits were implemented during a pedicle screw cervical spine fixation and hip arthroplasty performed on a porcine and ovine cadaver respectively. In both procedures, the universal non-circular orbits noticeably reduced the metal artifacts surrounding the implanted orthopedic hardware, revealing anatomy and soft tissue obscured in current conventional CBCT imaging. This work represents a key step in clinically translating universal orbits, unlocking high quality in-room procedural verification to increase broader use of robotic CBCT systems and reduce the occurrence of secondary corrective surgeries.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- University of Sydney, Sydney, Australia. tess.reynolds@sydney.edu.au.
- Johns Hopkins University, Baltimore, USA.
- Westmead Hospital, Sydney, Australia.
- University of Sydney, Sydney, Australia.
- OSSIS Corporation, Christchurch, New Zealand.
- Univestiy of Pennsylvania, Philadelphia, USA.
Förderung
- NIBIB NIH HHS
- Cancer Institute NSW
- NIH HHS
- National Institutes of Health
Zitieren
APA
Reynolds, T., Ma, Y., Kanawati, A., Dillon, O., Baer, K., Gang, G., & Stayman, J. (2024). Universal non-circular cone beam CT orbits for metal artifact reduction imaging during image-guided procedures. Scientific Reports. https://doi.org/10.1038/s41598-024-77964-9
Vancouver
Reynolds T, Ma Y, Kanawati A, Dillon O, Baer K, Gang G, et al. Universal non-circular cone beam CT orbits for metal artifact reduction imaging during image-guided procedures. Scientific Reports. 2024. doi:10.1038/s41598-024-77964-9
BibTeX
@article{Reynolds2024,
author = {Reynolds, Tess and Ma, Yiqun and Kanawati, Andrew and Dillon, Owen and Baer, Kenzie and Gang, Grace and Stayman, Joseph},
title = {Universal non-circular cone beam CT orbits for metal artifact reduction imaging during image-guided procedures},
journal = {Scientific Reports},
year = {2024},
doi = {10.1038/s41598-024-77964-9}
}
EUVIMED