Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2024. Verfasst von Wenqi Zhou und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA. Hauptthemen laut MEDLINE: Deep Learning, Imaging, Three-Dimensional, Needles. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, Siemens Medical Solutions USA, National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
Purpose
Accurate and rapid needle localization on 3D magnetic resonance imaging (MRI) is critical for MRI-guided percutaneous interventions. The current workflow requires manual needle localization on 3D MRI, which is time-consuming and cumbersome. Automatic methods using 2D deep learning networks for needle segmentation require manual image plane localization, while 3D networks are challenged by the need for sufficient training datasets. This work aimed to develop an automatic deep learning-based pipeline for accurate and rapid 3D needle localization on in vivo intra-procedural 3D MRI using a limited training dataset.
Methods
The proposed automatic pipeline adopted Shifted Window (Swin) Transformers and employed a coarse-to-fine segmentation strategy: (1) initial 3D needle feature segmentation with 3D Swin UNEt TRansfomer (UNETR); (2) generation of a 2D reformatted image containing the needle feature; (3) fine 2D needle feature segmentation with 2D Swin Transformer and calculation of 3D needle tip position and axis orientation. Pre-training and data augmentation were performed to improve network training. The pipeline was evaluated via cross-validation with 49 in vivo intra-procedural 3D MR images from preclinical pig experiments. The needle tip and axis localization errors were compared with human intra-reader variation using the Wilcoxon signed rank test, with p < 0.05 considered significant.
Results
The average end-to-end computational time for the pipeline was 6 s per 3D volume. The median Dice scores of the 3D Swin UNETR and 2D Swin Transformer in the pipeline were 0.80 and 0.93, respectively. The median 3D needle tip and axis localization errors were 1.48 mm (1.09 pixels) and 0.98°, respectively. Needle tip localization errors were significantly smaller than human intra-reader variation (median 1.70 mm; p < 0.01).
Conclusion
The proposed automatic pipeline achieved rapid pixel-level 3D needle localization on intra-procedural 3D MRI without requiring a large 3D training dataset and has the potential to assist MRI-guided percutaneous interventions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA.
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA.
- Joint Department of Medical Imaging, Sinai Health System and University of Toronto, Toronto, Canada.
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA. HoldenWu@mednet.ucla.edu.
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA. HoldenWu@mednet.ucla.edu.
ORCID-Profile: Holden H Wu
Förderung
- NIBIB NIH HHS
- Siemens Medical Solutions USA
- National Institute of Biomedical Imaging and Bioengineering
- David Geffen School of Medicine, University of California, Los Angeles
Zitieren
APA
Zhou, W., Li, X., Zabihollahy, F., Lu, D. S., & Wu, H. H. (2024). Deep learning-based automatic pipeline for 3D needle localization on intra-procedural 3D MRI. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-024-03077-3
Vancouver
Zhou W, Li X, Zabihollahy F, Lu DS, Wu HH. Deep learning-based automatic pipeline for 3D needle localization on intra-procedural 3D MRI. International Journal of Computer Assisted Radiology and Surgery. 2024. doi:10.1007/s11548-024-03077-3
BibTeX
@article{Zhou2024,
author = {Zhou, Wenqi and Li, Xinzhou and Zabihollahy, Fatemeh and Lu, David S and Wu, Holden H},