Lean body weight-based contrast injection protocol in liver CT: optimization of contrast medium dose
La radiologia medica · 2024
DOI: 10.1007/s11547-024-01944-2 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift La radiologia medica, 2024. Verfasst von Damiano Caruso und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical-Surgical Sciences and Translational Medicine, Sapienza University of Rome - Radiology Unit - Sant'Andrea University Hospital, V…. Hauptthemen laut MEDLINE: Contrast Media, Tomography, X-Ray Computed, Body Weight, Liver. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: To evaluate liver enhancement and image quality of abdominal CECT examinations acquired with multiple LBW-based contrast medium injection protocols. MATERIAL & METHODS: One hundred fifty patients who underwent a clinically indicated CECT examination were prospectively and randomly assigned to one of the following contrast medium injection protocol groups: A, 700 mg iodine(I)/kg of LBW; B, 650 mgI/kg of LBW; and C, 600 mgI/kg of LBW. Liver signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and magnitude of contrast enhancement (ΔHU) were calculated. Subjective image quality was assessed with 5-point Likert scale. RESULTS: The final population included 145 patients (64 females), with 50, 48, and 47 in group A, B, and C, respectively. Group A showed significantly higher SNR, CNR and ΔHU than group B (p = .018, p = .004, and p = .031, respectively) and group C (p = .024, p = .043, and p = .004). Group B had similar SNR, CNR, and ΔHU to group C (all p = 1). ΔHU was < 50 HU in 2, 7, and 11 patients in group A (48.2 ± 0.1), B (43.7 ± 5), and C (44.4 ± 5), respectively. Group A achieved the highest scores in terms of overall image quality, artifacts, and diagnostic confidence (both scores: 4; IQRs: 4-5) compared to group B (both scores: 3; IQRs: 3-5; p ≥ .037) and group C (overall image quality score: 3; IQR: 2-5; p = .011. Artifact and diagnostic confidence score: 3; IQR: 1-4; p ≥ .009). CONCLUSIONS: A dosage of 700 mgI/kg of LBW yields optimal liver enhancement and grants higher image quality compared to lower contrast medium dosages.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical-Surgical Sciences and Translational Medicine, Sapienza University of Rome - Radiology Unit - Sant'Andrea University Hospital, Via Di Grottarossa, 1035-1039, 00189, Rome, Italy.
- Department of Medical-Surgical Sciences and Translational Medicine, Sapienza University of Rome - Radiology Unit - Sant'Andrea University Hospital, Via Di Grottarossa, 1035-1039, 00189, Rome, Italy. andrea.laghi@uniroma…
ORCID-Profile: Damiano Caruso, Domenico De Santis, Antonella Del Gaudio, Daniela Valanzuolo, Dominga Pugliese, Marta Zerunian, Michela Polici, Giuseppe Tremamunno, Benedetta Masci
Zitieren
APA
Caruso, D., De Santis, D., Del Gaudio, A., Valanzuolo, D., Pugliese, D., Zerunian, M., Polici, M., Tremamunno, G., Masci, B., & Laghi, A. (2024). Lean body weight-based contrast injection protocol in liver CT: optimization of contrast medium dose. La radiologia medica. https://doi.org/10.1007/s11547-024-01944-2
Vancouver
Caruso D, De Santis D, Del Gaudio A, Valanzuolo D, Pugliese D, Zerunian M, et al. Lean body weight-based contrast injection protocol in liver CT: optimization of contrast medium dose. La radiologia medica. 2024. doi:10.1007/s11547-024-01944-2
BibTeX
@article{Caruso2024,
author = {Caruso, Damiano and De Santis, Domenico and Del Gaudio, Antonella and Valanzuolo, Daniela and Pugliese, Dominga and Zerunian, Marta and Polici, Michela and Tremamunno, Giuseppe and Masci, Benedetta and Laghi, Andrea},
title = {Lean body weight-based contrast injection protocol in liver CT: optimization of contrast medium dose},
journal = {La radiologia medica},
year = {2024},
doi = {10.1007/s11547-024-01944-2}
}