EUVIMEDEUVIMED entdecken
Crossref

The incremental value of histogram analysis in the differentiation between hyperdense cysts and solid renal masses on unenhanced CT images

Cecília Vidal de Souza Torres iD, André de Freitas Secaf iD, David Freire Maia Vieira iD, Alexandre Souto de Moraes Morgado iD, Matheus de Moraes Palma iD, Gabriel Andrade Ramos iD, Jorge Elias iD, Rodolfo B Reis iD, Valdair F Muglia iD

British Journal of Radiology · 2025

DOI: 10.1093/bjr/tqae198 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Radiology, 2025. Verfasst von Cecília Vidal de Souza Torres und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Imaging, Oncology and Hematology, Ribeirao Preto School of Medicine, University of Sao Paulo, Ribeirão Preto, São Paulo 14049-900, Braz…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Kidney Neoplasms, Kidney Diseases, Cystic. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To investigate the utility of voxel histogram analysis (HA) for differentiating hyperdense renal cysts from small solid masses on unenhanced CT scans.

Methods

A retrospective analysis of 99 hyperdense cystic lesions and 28 solid malignant lesions was conducted using a radiological database (from 2015 to 2021) and a pathological database (from 2010 to 2020). The study investigated the distribution of voxel attenuation values using percentiles to establish reliable criteria for differentiation after drawing a region of interest (ROI) in the centre of the lesions. The standard of reference was a histopathological diagnosis for malignant masses and contrast-enhanced CT or MRI for cysts.

Results

HA provided higher diagnostic accuracy than the conventional mean attenuation value of 70 Hounsfield Units (HU). For the 75th and 90th percentiles ± 1 standard deviation, accuracies of 77.2% (95% confidence interval 68.9%-84.2%) for the 75th and 68.5% (59.7%-76.4%) for the 90th were found, versus 37.0% (28.6%-46.0%) for the 70 HU threshold criterion. A Gaussian distribution of voxel attenuation values was observed in 88.9% of the lesions, suggesting that it is feasible to calculate these parameters from a single measurement.

Conclusion

The study underscores the potential of HA as a valuable tool for characterizing hyperdense cysts on unenhanced CT by using the same ROI for measuring lesion attenuation. HA could offer additional value beyond the 70 HU criterion and possibly influence clinical decisions. Multi-institutional studies are necessary for external validation to confirm its generalizability and more extensive applicability. Advances in knowledge (1) A single measurement on unenhanced CT images, using mean attenuation and standard deviation, accurately reflects the voxel distribution of both cystic and solid masses, allowing for the application of histogram analysis. (2) The 75th percentile threshold of 65 HU or higher could potentially increase sensitivity in diagnosing hyperdense cysts, compared to the 70 HU mean attenuation threshold, without compromising specificity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedKidney NeoplasmsKidney Diseases, CysticHumansRetrospective StudiesFemaleMaleMiddle AgedDiagnosis, DifferentialAgedAdultAged, 80 and overKidney

Stichwörter der Autor:innen

computed tomographyhistogram analysishyperdense renal cystsrenal massesrenal tumors

Autor:innen und Institutionen

  • Department of Imaging, Oncology and Hematology, Ribeirao Preto School of Medicine, University of Sao Paulo, Ribeirão Preto, São Paulo 14049-900, Brazil.
  • Department of Surgery and Anatomy, Urology Division, Ribeirao Preto School of Medicine, University of Sao Paulo, Ribeirão Preto, São Paulo 14049-900, Brazil.

ORCID-Profile: Cecília Vidal de Souza Torres, André de Freitas Secaf, David Freire Maia Vieira, Alexandre Souto de Moraes Morgado, Matheus de Moraes Palma, Gabriel Andrade Ramos, Jorge Elias, Rodolfo B Reis, Valdair F Muglia

Zitieren

APA

de Souza Torres, C. V., de Freitas Secaf, A., Maia Vieira, D. F., de Moraes Morgado, A. S., de Moraes Palma, M., Andrade Ramos, G., Elias, J., Reis, R. B., & Muglia, V. F. (2025). The incremental value of histogram analysis in the differentiation between hyperdense cysts and solid renal masses on unenhanced CT images. British Journal of Radiology. https://doi.org/10.1093/bjr/tqae198

Vancouver

de Souza Torres CV, de Freitas Secaf A, Maia Vieira DF, de Moraes Morgado AS, de Moraes Palma M, Andrade Ramos G, et al. The incremental value of histogram analysis in the differentiation between hyperdense cysts and solid renal masses on unenhanced CT images. British Journal of Radiology. 2025. doi:10.1093/bjr/tqae198

BibTeX
@article{deSouzaTorres2025,
  author = {de Souza Torres, Cecília Vidal and de Freitas Secaf, André and Maia Vieira, David Freire and de Moraes Morgado, Alexandre Souto and de Moraes Palma, Matheus and Andrade Ramos, Gabriel and Elias, Jorge and Reis, Rodolfo B and Muglia, Valdair F},
  title = {The incremental value of histogram analysis in the differentiation between hyperdense cysts and solid renal masses on unenhanced CT images},
  journal = {British Journal of Radiology},
  year = {2025},
  doi = {10.1093/bjr/tqae198}
}
Kostenlos starten →