Optimization of three-dimensional esophageal tumor ablation by simultaneous functioning of multiple electrodes

Hongying Wang, Jincheng Zou, Shiqing Zhao, Aili Zhang

Medical & Biological Engineering & Computing · 2025

DOI: 10.1007/s11517-024-03230-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical & Biological Engineering & Computing, 2025. Verfasst von Hongying Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. Hauptthemen laut MEDLINE: Esophageal Neoplasms, Catheter Ablation, Radiofrequency Ablation. Die Arbeit nennt 51 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Radiofrequency ablation is a widely accepted minimal-invasive and effective local treatment for tumors. However, its current application in esophageal cancer treatment is limited to targeting thin and superficial lesions, such as Barrett's Esophagus. This study proposes an optimization method using multiple electrodes simultaneously to regulate the temperature field and achieve conformal ablation of tumors. A particle swarm optimization algorithm, coupled with a three-dimensional thermal ablation model, was developed to optimize the status of the functioning electrodes, the optimal voltage (Vopt), and treatment duration (ttre) for targeted esophageal tumors. This approach takes into account both the electrical and thermal interactions of the electrodes. The results indicate that for esophageal cancers at various stages, with thickness (c) ranging from 4.5 mm to 10.0 mm, major axis (a) ranging from 7.3 mm to 27.3 mm, and minor axis (b) equaling 7.3 mm or 27.3 mm, as well as non-symmetrical geometries, complete tumor coverage (over 99.5%) close to conformal can be achieved. This method illustrates possible precise conformal ablation of esophageal cancers and it may also be used for conformal treatments of other intraluminal lesions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Esophageal NeoplasmsCatheter AblationRadiofrequency AblationHumansElectrodesAlgorithmsImaging, Three-Dimensional

Stichwörter der Autor:innen

Esophageal tumorMultielectrodeOptimizationRadiofrequency ablation

Autor:innen und Institutionen

  • School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. shiqingzhao@sjtu.edu.cn.
  • School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. zhangaili@sjtu.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Wang, H., Zou, J., Zhao, S., & Zhang, A. (2025). Optimization of three-dimensional esophageal tumor ablation by simultaneous functioning of multiple electrodes. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-024-03230-9

Vancouver

Wang H, Zou J, Zhao S, Zhang A. Optimization of three-dimensional esophageal tumor ablation by simultaneous functioning of multiple electrodes. Medical & Biological Engineering & Computing. 2025. doi:10.1007/s11517-024-03230-9

BibTeX
@article{Wang2025,
  author = {Wang, Hongying and Zou, Jincheng and Zhao, Shiqing and Zhang, Aili},
  title = {Optimization of three-dimensional esophageal tumor ablation by simultaneous functioning of multiple electrodes},
  journal = {Medical & Biological Engineering & Computing},
  year = {2025},
  doi = {10.1007/s11517-024-03230-9}
}
Kostenlos starten →