Fachartikel in der Zeitschrift Experimental Mechanics, online erschienen am 06.03.2026. Verfasst von S. Wang und 4 weiteren Autor:innen. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swedish Centre for Nuclear Technology, Royal Institute of Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Analysis of finite elastic–plastic deformation requires a good constitutive description of the inelastic response. A key element is the hardening function, typically evaluated from nominal data obtained from a uniaxial tension test using the Bridgman correction method in the post-necking regime. However, the true stress–strain data obtained in this way depend crucially on the quality of the optical measurements. Based on modern and sophisticated technology, several new and demanding methods have emerged over the last decade to improve the accuracy of the Bridgman correction method.

Objective

To develop and validate an accurate method, combining standard experimental and numerical methods for the evaluation of the true stress–strain response of an elastic–plastic material.

Method

Experimental force-displacement data for a gauge section of a round bar specimen are used as input to an inverse finite interval (IFI) method to construct the true stress-strain response at discrete points by minimising the relative error between finite element simulations and experimental results.

Results

The inverse finite interval method is validated both numerically and experimentally. Synthetic force–displacement data are generated numerically for a set of power-law hardening materials, and the proposed method is then applied to reconstruct the true stress–strain curve. The method is proven to be robust, and reconstructed true stress–strain curves converge to the exact power-law function. Three markedly different steel grades are used for experimental validation by comparing the deformed geometry in the necking region between experimental and numerical results, showing good agreement.

Conclusion

The proposed inverse finite interval (IFI) method is an expedient and accurate method for evaluation of the true stress–strain curve from nominal data extracted from a uniaxial tension test.

Förderung

  • Swedish Centre for Nuclear Technology
  • Royal Institute of Technology

Zitieren

APA

Wang, S., Boåsen, M., Hultgren, G., Öberg, M., & Faleskog, J. (2026). An Inverse Finite Interval Method for Evaluating the True Stress–Strain Response from Uniaxial Tension Tests. Experimental Mechanics, 66(3), 551-565. https://doi.org/10.1007/s11340-026-01266-6

Vancouver

Wang S, Boåsen M, Hultgren G, Öberg M, Faleskog J. An Inverse Finite Interval Method for Evaluating the True Stress–Strain Response from Uniaxial Tension Tests. Experimental Mechanics. 2026;66(3):551-565. doi:10.1007/s11340-026-01266-6

BibTeX
@article{Wang2026,
  author = {Wang, S. and Boåsen, M. and Hultgren, G. and Öberg, M. and Faleskog, J.},
  title = {An Inverse Finite Interval Method for Evaluating the True Stress–Strain Response from Uniaxial Tension Tests},
  journal = {Experimental Mechanics},
  year = {2026},
  volume = {66},
  number = {3},
  pages = {551--565},
  doi = {10.1007/s11340-026-01266-6}
}
Kostenlos starten →