Scanning resolution influences texture features in intraoral radiographs
Oral Radiology · 2026-07 · 42 (3) · 820-828
DOI: 10.1007/s11282-026-00922-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Oral Radiology, online erschienen am 12.05.2026. Verfasst von Bianca Costa Goncalves und 7 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Science and Technology, Department of Diagnosis and Surgery, São Paulo State University (UNESP), Engenheiro Francisco José Longo Avenue,…. Hauptthemen laut MEDLINE: Radiography, Dental, Digital. Die Arbeit nennt 25 Literaturangaben. Gefördert von: Fundação de Amparo à Pesquisa do Estado de São Paulo , Brasil, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Abstract (Originalsprache)
OBJECTIVES: To evaluate the influence of different spatial scanning resolutions of photostimulable phosphor (PSP) plates on digital radiographic images using texture analysis (TA). MATERIALS AND METHODS: Digital radiographs of an aluminum step wedge with five steps (0.5 mm increments) were acquired at two radiographic exposure times (0.10 and 0.20 s). Each image was scanned at four different spatial resolutions (10, 20, 25, and 40 lp/mm), with 10 repetitions per condition. Regions of interest (ROIs) were placed on the steps with thicknesses of 0.5, 1.5, and 2.5 mm. Texture features based on the gray-level co-occurrence matrix (GLCM) were extracted using MaZda 4.6 software. Exploratory data analysis was performed, and spatial resolutions were compared within each combination of exposure time and object thickness using ANOVA, followed by Tukey's post-hoc test (p < 0.05). RESULTS: At 0.10 s exposure, eight texture parameters exhibited statistically significant differences among spatial resolutions, independent of object thickness, with higher values observed at 10 and 20 lp/mm. For an exposure of 0.20 s, two parameters also showed significant differences across resolutions, with higher values at lower resolutions. CONCLUSIONS: TA revealed that, in the tested PSP system, lower scanning resolutions resulted in images with reduced homogeneity and uniformity, regardless of object thickness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Science and Technology, Department of Diagnosis and Surgery, São Paulo State University (UNESP), Engenheiro Francisco José Longo Avenue, 777, Jardim São Dimas, São José dos Campos, São Paulo, 12245-000, Bra…
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Mevlana, 19/1, Emniyet, 06560, Yenimahalle, Ankara, Turkey.
- Postgraduate Program in Dentistry, Cruzeiro do Sul University (UNICSUL), Galvão Bueno Street, 868, Liberdade, São Paulo, São Paulo, 01506-000, Brazil.
Förderung
- Fundação de Amparo à Pesquisa do Estado de São Paulo , Brasil
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zitieren
APA
Goncalves, B. C., Beckmann, P. S., de Oliveira, V. G. B., Santos, L. F., Correa, V. A. A., Orhan, K., Costa, A. L. F., & de Castro Lopes, S. L. P. (2026). Scanning resolution influences texture features in intraoral radiographs. Oral Radiology, 42(3), 820-828. https://doi.org/10.1007/s11282-026-00922-w
Vancouver
Goncalves BC, Beckmann PS, de Oliveira VGB, Santos LF, Correa VAA, Orhan K, et al. Scanning resolution influences texture features in intraoral radiographs. Oral Radiology. 2026;42(3):820-828. doi:10.1007/s11282-026-00922-w
BibTeX
@article{Goncalves2026,
author = {Goncalves, Bianca Costa and Beckmann, Pedro Santos and de Oliveira, Victoria Geisa Brito and Santos, Lana Ferreira and Correa, Vitoria Aparecida Amorim and Orhan, Kaan and Costa, André Luiz Ferreira and de Castro Lopes, Sérgio Lúcio Pereira},
title = {Scanning resolution influences texture features in intraoral radiographs},
journal = {Oral Radiology},
year = {2026},
volume = {42},
number = {3},
pages = {820--828},
doi = {10.1007/s11282-026-00922-w}
}
EUVIMED