Clinical evaluation of a digital stethoscope with simultaneous phonocardiography and electrocardiography in cats
Veterinary Research Communications · 2025
DOI: 10.1007/s11259-024-10600-z ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Research Communications, 2025. Verfasst von Lisa Alibrandi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Sciences, University of Pisa, via Livornese, San Piero a Grado, Pisa, 56122, Italy. Hauptthemen laut MEDLINE: Stethoscopes, Electrocardiography, Cat Diseases. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
A smartphone-based technology combining a digital stethoscope (DS) with simultaneous phonocardiography (PCG) and 1-lead electrocardiogram (ECG) is available. The aim of the present study was to evaluate the sensitivity and specificity of the DS for the detection of heart disease in cats considering transthoracic echocardiography as gold standard. The study is prospective and observational inlcuding 42 client-owned cats. All cases underwent auscultation with a conventional stethoscope (CS), recording with the DS, 6-lead ECG and echocardiography. All the recordings were blindly reviewed. The agreement with standard methods was assessed using the Cohen's kappa and the Bland-Altman test. The Fisher's exact test was used to test the effect of shaving on tracings' quality. Intraoperator and interoperator variability were assessed with Cohen's k and Fleiss' k, respectively. Audio recordings obtained with DS were interpretable in 100% of the cats. The agreement between DS and echocardiography in detecting heart disease was substantial (k = 0.714), while between CS and echocardiography the agreement was moderate (k = 0.571). Intraoperator and interoperator agreement was almost perfect (k = 0.904; k = 0.867, respectively). The ECG tracings recorded with the DS were interpretable in 83% of the cats and the device was reliable in assessing basic ECG measurements. No significant differences were found in the quality of the audio and ECG tracings in relation to the shaving condition. Based on the efficacy of detecting cardiac murmurs and gallop sound, the DS can be considered a reliable tool for cardiac auscultation in cats, producing good quality audio and ECG tracings also suitable for possible remote interpretation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Veterinary Sciences, University of Pisa, via Livornese, San Piero a Grado, Pisa, 56122, Italy.
- Unit of Translational Critical Care Medicine, Department of Health Science, School of Advanced Studies Sant'Anna, Piazza Martiri della Libertà 56127, Pisa, Italy.
- Department of Veterinary Sciences, University of Pisa, via Livornese, San Piero a Grado, Pisa, 56122, Italy. tommaso.vezzosi@unipi.it.
- Anicura Istituto Veterinario Novara, Strada Provinciale, Granozzo con Monticello 20060, Novara, Italy.
Zitieren
APA
Alibrandi, L., Vezzosi, T., Bozzolo, E., Grosso, G., Domenech, O., & Tognetti, R. (2025). Clinical evaluation of a digital stethoscope with simultaneous phonocardiography and electrocardiography in cats. Veterinary Research Communications. https://doi.org/10.1007/s11259-024-10600-z
Vancouver
Alibrandi L, Vezzosi T, Bozzolo E, Grosso G, Domenech O, Tognetti R. Clinical evaluation of a digital stethoscope with simultaneous phonocardiography and electrocardiography in cats. Veterinary Research Communications. 2025. doi:10.1007/s11259-024-10600-z
BibTeX
@article{Alibrandi2025,
author = {Alibrandi, Lisa and Vezzosi, Tommaso and Bozzolo, Eliana and Grosso, Giovanni and Domenech, Oriol and Tognetti, Rosalba},
title = {Clinical evaluation of a digital stethoscope with simultaneous phonocardiography and electrocardiography in cats},
journal = {Veterinary Research Communications},
year = {2025},
doi = {10.1007/s11259-024-10600-z}
}
EUVIMED