Clot waveform analysis in haemostatic and systemic disorders: current applications and clinical potential
Journal of Thrombosis and Thrombolysis · 30.10.2026
DOI: 10.1007/s11239-026-03416-y ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Thrombosis and Thrombolysis, online erschienen am 30.10.2026. Verfasst von Norliana Ghazali und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Dental Sciences, USM Health Campus, Universiti Sains Malaysia, 16150, Kelantan, Kota Bharu, Malaysia. Die Arbeit nennt 21 Literaturangaben. Gefördert von: National Kidney Foundation Malaysia.
Abstract (Originalsprache)
Clot waveform analysis (CWA), originate from conventional coagulation assays, particularly the activated partial thromboplastin time (APTT) and prothrombin time (PT), offers enhanced sensitivity and dynamic profiling of haemostatic processes. By capturing real-time changes in clot formation kinetics, CWA patterns provide disease specific changes beyond traditional clotting time. It has potential clinical utility in identifying bleeding risk in inherited and acquired bleeding disorders, as well as prothrombotic states in condition such as infections and myocardial infarction. A unique APTT second-derivative curves have been reported in COVID-19 infection. In malignancy, it may help clinicians to mitigate the risk of developing thrombotic complications due to cancer-associated hypercoagulability. This review covers the principles, analytical parameters, and clinical applications of CWA. As evidence continues to grow, integrating CWA into standard coagulation testing algorithms, particularly with the use of artificial intelligence, may potentially lead to improvements in patient stratification, monitoring and management in both acute and chronic haemostatic disorders. Graphical Abstract
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Dental Sciences, USM Health Campus, Universiti Sains Malaysia, 16150, Kelantan, Kota Bharu, Malaysia.
- School of Dental Sciences, USM Health Campus, Universiti Sains Malaysia, 16150, Kelantan, Kota Bharu, Malaysia. suriana@usm.my.
- Department of Haematology, Hospital Universiti Sains Malaysia, Kota Bharu, Malaysia. suriana@usm.my.
- Department of Haematology, Hospital Universiti Sains Malaysia, Kota Bharu, Malaysia. salfarina@usm.my.
- Department of Haematology, School of Medical Sciences, USM Health Campus, Universiti Sains Malaysia, 16150, Kelantan, Kota Bharu, Malaysia. salfarina@usm.my.
- Department of Haematology, School of Medical Sciences, USM Health Campus, Universiti Sains Malaysia, 16150, Kelantan, Kota Bharu, Malaysia.
Förderung
- National Kidney Foundation Malaysia
Zitieren
APA
Ghazali, N., Wan Ab Rahman, W. S., Iberahim, S., Venkatesan, G., Hassan, M. N., Zulkafli, Z., & Abdullah, M. (2026). Clot waveform analysis in haemostatic and systemic disorders: current applications and clinical potential. Journal of Thrombosis and Thrombolysis. https://doi.org/10.1007/s11239-026-03416-y
Vancouver
Ghazali N, Wan Ab Rahman WS, Iberahim S, Venkatesan G, Hassan MN, Zulkafli Z, et al. Clot waveform analysis in haemostatic and systemic disorders: current applications and clinical potential. Journal of Thrombosis and Thrombolysis. 2026. doi:10.1007/s11239-026-03416-y
BibTeX
@article{Ghazali2026,
author = {Ghazali, Norliana and Wan Ab Rahman, Wan Suriana and Iberahim, Salfarina and Venkatesan, Gokulakannan and Hassan, Mohd Nazri and Zulkafli, Zefarina and Abdullah, Marne},
title = {Clot waveform analysis in haemostatic and systemic disorders: current applications and clinical potential},
journal = {Journal of Thrombosis and Thrombolysis},
year = {2026},
doi = {10.1007/s11239-026-03416-y}
}
EUVIMED