Decoding Clot Waveform Analysis: Toward Better Understanding and Harmonization
Seminars in Thrombosis and Hemostasis · 2026-06 · 52 (04) · 460-475
DOI: 10.1055/a-2778-9810 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Seminars in Thrombosis and Hemostasis, online erschienen am 21.01.2026. Verfasst von Jing Yuan Tan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Haematology, Singapore General Hospital, Singapore. Hauptthemen laut MEDLINE: Blood Coagulation, Prothrombin Time. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Clot waveform analysis (CWA) extends routine coagulation assays (activated partial thromboplastin time [aPTT] and prothrombin time [PT]) by incorporating continuous optical monitoring to generate kinetic profiles of clot formation. This method provides both qualitative and quantitative information on hemostasis, with increasing evidence for its clinical utility in detecting factor deficiencies and characterizing thrombotic and bleeding disorders. Despite the growing body of evidence, translation of CWA into routine clinical practice remains limited. This review identifies three principal barriers: (1) variability arising from differences in optical detection methods (absorbance vs. transmittance), (2) interreagent variation even within the same analyzer platform, and (3) lack of a clear distinction between standard CWA, performed with commercially available reagents, and modified CWA, incorporating in-house adjustments. To address these challenges, we encourage adopting distinct nomenclature for detection modalities (CWA-A; A for absorbance and CWA-T; T for transmittance), establishing standardized reporting requirements including reagent and platform details, and establishing quality assurance frameworks for CWA. Standardization of terminology and reporting will enhance reproducibility, enable cross-study comparisons, and accelerate the clinical translation of CWA from the laboratory bench to the bedside.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Haematology, Singapore General Hospital, Singapore.
ORCID-Profile: Marvin Raden Torres De Guzman
Zitieren
APA
Tan, J. Y., De Guzman, M. R. T., Wong, W. H., Yeo, C. K., Goh, G. H., Ng, H. J., & Tan, C. W. (2026). Decoding Clot Waveform Analysis: Toward Better Understanding and Harmonization. Seminars in Thrombosis and Hemostasis, 52(04), 460-475. https://doi.org/10.1055/a-2778-9810
Vancouver
Tan JY, De Guzman MRT, Wong WH, Yeo CK, Goh GH, Ng HJ, et al. Decoding Clot Waveform Analysis: Toward Better Understanding and Harmonization. Seminars in Thrombosis and Hemostasis. 2026;52(04):460-475. doi:10.1055/a-2778-9810
BibTeX
@article{Tan2026,
author = {Tan, Jing Yuan and De Guzman, Marvin Raden Torres and Wong, Wan Hui and Yeo, Chi Kiat and Goh, Guan Hao and Ng, Heng Joo and Tan, Chuen Wen},
title = {Decoding Clot Waveform Analysis: Toward Better Understanding and Harmonization},
journal = {Seminars in Thrombosis and Hemostasis},
year = {2026},
volume = {52},
number = {04},
pages = {460--475},
doi = {10.1055/a-2778-9810}
}