Patient experiences with a smartwatch 1L-ECG versus traditional Holter monitoring for ambulatory cardiac rhythm monitoring: a qualitative study
BMJ Open · 2025
DOI: 10.1136/bmjopen-2025-101557 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift BMJ Open, 2025. Verfasst von Evert P M Karregat und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Practice, Amsterdam UMC Location AMC, Amsterdam, Netherlands e.p.karregat@amsterdamumc.nl. Hauptthemen laut MEDLINE: Electrocardiography, Ambulatory, Arrhythmias, Cardiac, Wearable Electronic Devices, Patient Satisfaction. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Stichting Stoffels-Hornstra.
Abstract (Originalsprache)
Objective
To explore patients’ experiences and perspectives on using a direct-to-consumer smartwatch with single-lead electrocardiography (1L-ECG) for ambulatory rhythm diagnostics in primary care.
Design
Qualitative study using semi-structured interviews and thematic analysis.
Setting
Primary care patients referred for ambulatory rhythm monitoring in a diagnostic centre. Participant Eighteen adults with paroxysmal palpitations, of whom nine were female patients (50%), aged 32–85 (median 66) years.
Intervention
Participants simultaneously wore a smartwatch with 1L-ECG capability (Withings ScanWatch) and a conventional Holter monitor for 7 days. Outcome measures Patient experiences and perceived barriers and facilitators to smartwatch use for rhythm monitoring, reported after the monitoring period.
Results
Patients found the smartwatch more user-friendly and feasible than the Holter monitor. Difficulties included uncertainty about when to initiate recordings, challenges capturing brief episodes and anxiety triggered by automated algorithm outputs. Participants emphasised the importance of accessible healthcare support for interpretation and reassurance.
Conclusions
This study shows that smartwatch-based 1L-ECG monitoring is feasible and acceptable for ambulatory rhythm diagnostics in primary care. Prior to routine implementation, it is crucial to address the identified challenges: particularly anxiety related to algorithm results, uncertainty about when to record and accessible clinician support.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of General Practice, Amsterdam UMC Location AMC, Amsterdam, Netherlands e.p.karregat@amsterdamumc.nl.
- Personalized Medicine, Amsterdam Public Health Research Institute, Amsterdam, Netherlands.
- Department of General Practice, Amsterdam UMC Location AMC, Amsterdam, Netherlands.
- Department of Cardiology, Dijklander Hospital, Hoorn, Netherlands.
- Department of Public and Occupational Health, University of Amsterdam, Amsterdam, Netherlands.
Förderung
- Stichting Stoffels-Hornstra
Zitieren
APA
Karregat, E. P. M., Vooijs, P., Wierda, E., Harskamp, R., Lucassen, W., Himmelreich, J. C. L., & Moll van Charante, E. P. (2025). Patient experiences with a smartwatch 1L-ECG versus traditional Holter monitoring for ambulatory cardiac rhythm monitoring: a qualitative study. BMJ Open. https://doi.org/10.1136/bmjopen-2025-101557
Vancouver
Karregat EPM, Vooijs P, Wierda E, Harskamp R, Lucassen W, Himmelreich JCL, et al. Patient experiences with a smartwatch 1L-ECG versus traditional Holter monitoring for ambulatory cardiac rhythm monitoring: a qualitative study. BMJ Open. 2025. doi:10.1136/bmjopen-2025-101557
BibTeX
@article{Karregat2025,
author = {Karregat, Evert P M and Vooijs, Pieter and Wierda, Eric and Harskamp, Ralf and Lucassen, Wim and Himmelreich, Jelle C L and Moll van Charante, Eric P},
title = {Patient experiences with a smartwatch 1L-ECG versus traditional Holter monitoring for ambulatory cardiac rhythm monitoring: a qualitative study},
journal = {BMJ Open},
year = {2025},
doi = {10.1136/bmjopen-2025-101557}
}
EUVIMED