Capnodynamic determination of end-expiratory lung volume in a porcine model of hypoxic pulmonary vasoconstriction
Journal of Clinical Monitoring and Computing · 2024
DOI: 10.1007/s10877-024-01251-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Monitoring and Computing, 2024. Verfasst von Aron Törnwall und 4 weiteren Autor:innen. Beteiligte Einrichtung: Pediatric perioperative medicine and Intensive Care, Karolinska University Hospital, Eugeniavägen 23, Stockholm, 171 64, Sweden. Hauptthemen laut MEDLINE: Vasoconstriction, Hypoxia, Lung, Lung Volume Measurements. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Karolinska Institute.
Abstract (Originalsprache)
Purpose
The capnodynamic method, End Expiratory Lung Volume CO 2 (EELV-CO 2 ), utilizes exhaled carbon dioxide analysis to estimate End-Expiratory Lung Volume (EELV) and has been validated in both normal lungs and lung injury models. Its performance under systemic hypoxia and variations in CO 2 elimination is not examined. This study aims to validate EELV-CO 2 against inert gas wash in/wash out (EELV- SF6, sulfur hexafluoride) in a porcine model of stable hemodynamic conditions followed by hypoxic pulmonary vasoconstriction and inhaled nitric oxide (iNO).
Methods
Ten mechanically ventilated piglets were exposed to a hypoxic gas mixture and selective pulmonary vasoconstriction. Inhalation of nitric oxide was used to reverse the pulmonary vasoconstriction. Paired recordings of EELV-CO 2 and EELV-SF6, were conducted to assess their agreement of absolute values.
Results
EELV-CO 2 showed a bias of + 5 ml kg − 1 compared to EELV-SF6, upper limit of agreement of 11 ml kg − 1 (95%CI: 9–13 ml kg − 1 ), lower limit of agreement − 1 ml kg − 1 (95%CI: -3- 0 ml kg − 1 ), mean percentage error 34%. Agreement between EELV-CO 2 and EELV-SF6 was largely constant but was affected by progressing hypoxia and reached maximum limit of agreement after iNO exposure. Re-introduction of normoxemia then stabilized bias and limits of agreement to baseline levels.
Conclusion
EELV-CO 2 generates absolute values in parallel with EELV -SF6. Stressing EELV-CO 2 with hypoxic pulmonary vasoconstriction and iNO, transiently impairs the agreement which stabilizes once normoxemia is reestablished.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Pediatric perioperative medicine and Intensive Care, Karolinska University Hospital, Eugeniavägen 23, Stockholm, 171 64, Sweden.
- Karolinska Institute Department of Physiology and Pharmacology (FYFA), Lönnqvist group- Section of Anesthesiology and Intensive Care, Anestesi- och Intensivvårdsavdelningen, Stockholm, C3, 171 76, PA, Sweden.
- Maquet Critical Care AB, Röntgenvägen 2, Solna, 171 06, Sweden.
- Pediatric perioperative medicine and Intensive Care, Karolinska University Hospital, Eugeniavägen 23, Stockholm, 171 64, Sweden. jacob.karlsson.1@ki.se.
- Karolinska Institute Department of Physiology and Pharmacology (FYFA), Lönnqvist group- Section of Anesthesiology and Intensive Care, Anestesi- och Intensivvårdsavdelningen, Stockholm, C3, 171 76, PA, Sweden. jacob.karl…
ORCID-Profile: Magnus Hallbäck, Per-Arne Lönnqvist, Jacob Karlsson
Förderung
- Karolinska Institute
Zitieren
APA
Törnwall, A., Wallin, M., Hallbäck, M., Lönnqvist, P. A., & Karlsson, J. (2024). Capnodynamic determination of end-expiratory lung volume in a porcine model of hypoxic pulmonary vasoconstriction. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-024-01251-1
Vancouver
Törnwall A, Wallin M, Hallbäck M, Lönnqvist PA, Karlsson J. Capnodynamic determination of end-expiratory lung volume in a porcine model of hypoxic pulmonary vasoconstriction. Journal of Clinical Monitoring and Computing. 2024. doi:10.1007/s10877-024-01251-1
BibTeX
@article{Trnwall2024,
author = {Törnwall, Aron and Wallin, Mats and Hallbäck, Magnus and Lönnqvist, Per-Arne and Karlsson, Jacob},
title = {Capnodynamic determination of end-expiratory lung volume in a porcine model of hypoxic pulmonary vasoconstriction},
journal = {Journal of Clinical Monitoring and Computing},
year = {2024},
doi = {10.1007/s10877-024-01251-1}
}
EUVIMED